Specifications
Beech Ovens Page 105 28/07/2011 (C)
RND-REC-RGO Manual (R1) Confidential and Proprietary
5mm gap at Spark point
Flame Sensor probe slightly off
centre
If the position of the probes has been altered, be sure that the Flame Ignition probe
and Earth probe have an approximately 5mm gap between them at the Spark point.
These two (2) probes should NOT be close to any other metallic surface or close to
each other, other than at the Spark point as shown below.
The Flame Sensor probe should be slightly off centre.
Note: Be sure to check that all Gas lines, cabling and bolts are correctly
assembled and secured before turning on power and gas for re-start.
The gap between the burner
nozzle and the Tri-electrode
probes should be no closer than
8mm.