Overview of Primary Product
CG4
Gas Burner
8
Slant/Fin Intrepid
Appliance
Appliance
Input BTU
Beckett
Required
Input BTU
Burner
Chassis
Part #
Air Tube
Combination
Part #
Head Insertion
NG
Orifice
Size
LP
Orifice
Size Baffle
Air Settings
Shutter /Band
Air Band PN / Slot
Number
Notes
TR-30 140,000 140,000 CG4001 CG4SFF3 F3G 1.75" None 0.242 None S-8 / B-0 4 - slot 1
TR-40 210,000 190,000 CG4001 CG4SFF4 F4G 1.75" None 0.281 None S-10 / B-3 4 - slot
Appliance
Appliance
Input BTU
Beckett
Required
Input BTU
Burner
Chassis
Part #
Air Tube
Combination
Part # Head Insertion
NG
Orifice
Size
LP
Orifice
Size Baffle
Air Settings
Shutter /Band
Air Band PN / Slot
Number Notes
SFH-3085W 119,000 120,000 CG4001 CG4UTF3
F3G 2.25" 0.316 0.219 5880 S-10 / B-1 4 - slot 1
SFH-3100W 140,000 140,000 CG4001 CG4UTF3
F3G 2.25" None 0.242 None S-10 / B-0 4 - slot 1
SFH-4100W 140,000 145,000 CG4001 CG4UTF4 F4G 2.25" 0.316 0.234 5880 S-10 / B-3 4 - slot
Appliance
Appliance
Input BTU
Beckett
Required
Input BTU
Burner
Chassis
Part #
Air Tube
Combination
Part # Head Insertion
NG
Orifice
Size
LP
Orifice
Size Baffle
Air Settings
Shutter /Band
Air Band PN / Slot
Number Notes
OWB/OWT-4 140,000 145,000 CG4001 CG4WMF4 F4G 3.00" 0.316 0.234
5880
S-10 / B-1 4 - slot
OWB/OWT-4 168,000 160,000 CG4001 CG4WMF4 F4G 3.00" 0.348 0.246 None S-6.5 / B-0 4 - slot
OWB/OWT-5 168,000 175,000 CG4001 CG4WMF4 F4G 3.00" 0.406 0.261 None S-7.5 / B-0 4 - slot
OWB/OWT-5 203,000 190,000 CG4001 CG4WMF4 F4G 3.00" None 0.281 None S-10 / B-0 4 - slot
Notes Legend:
See Manual for operating pressure requirements.
Utica Starfire
Williamson
1) Blank Air Band included with Air Tube Combination.
2) Heat Exchanger Baffles Must Be Removed to Achieve Appropriate Flue
Temperature Above 325°F.