RESIDENTIAL & COMMERCIAL HEATING PRODUCTS CG4 Gas Burner Form No. 62069-001, Printed in the USA 10/15 Appliance Guide www.beckettcorp.
Before Calling a Manufacturer’s Tech Service . . . Before contacting us about your burner, you must have a completed copy of the Contractor Start-Up Form (located inside last page). This information is crucial for troubleshooting and obtaining the correct replacement parts. Professional Service Required Applicances have been tested or verified by Beckett but NOT tested or endorsed by the appliance manufacturer, unless noted.
ANSI Z21.17a Gas Conversion Burner Standard, requires specific warnings to be placed on the cover of all instruction manuals for gas conversion burners. Below are examples of these types of warnings which must be understood and followed.
CG4 Gas Burner Approvals The Beckett CG4 Gas Burner has been evaluated by UL and certified to meet the standards for Domestic Gas Conversion Burners for the US and for Canada. The applicable standards met are ANSI Z21.17a-1998 and CSA 2.7-M98 (AMERICAN NATIONAL STANDARD/CSA STANDARD FOR DOMESTIC GAS CONVERSION BURNERS) and they address the burner requirements for the conversion of oil-fired appliances to gas.
Safety Check-off List Recommendations Follow installation manual instructions. Verify incoming gas pressure. Verify the BTU rating of gas meter. Verify that the pipe size meets the input BTU rating of the appliance Verify combustion air supply meets code requirements (consult local authorities for prevailing codes). Verify that area around appliance is free of lint or pet hair. Verify condition and size of chimney and venting.
CG4 Gas Burner Buderus Appliance Burner Air Tube Beckett Appliance Required Chassis Combination Input BTU Input BTU Part # Part # Head Insertion NG Orifice Size LP Orifice Size Baffle Air Settings Air Band PN / Slot Shutter /Band Number Notes G115-3 96,000 90,000 CG4001 CG4BUF3 F3G 5.25" 0.234 0.177 5880 S-7 / B-0 Blank 1, 3 G115-4 126,000 130,000 CG4001 CG4BUF3 F3G 5.25" 0.364 0.234 None S-5 / B-0 4 - Slot 1, 3 G115-5 154,000 145,000 CG4001 CG4BUF4 F4G 5.25" 0.
CG4 Appliance KSZ075 KSZ100 Burner Air Tube Beckett Appliance Required Chassis Combination Part # Input BTU Input BTU Part # Head Insertion 105,000 140,000 NG Orifice Size LP Orifice Size Baffle Air Settings Air Band PN / Slot Shutter /Band Number Notes 110,000 CG4001 CG4SFF3 F3G 1.75" 0.277 0.206 5880 S-7 / B-0 Blank 1 140,000 CG4001 CG4SFF3 F3G 1.75" None 0.242 None S-7-1/2 / B-0 4 - Slot 1 CG4SFF4 F4G 1.75" 0.348 0.246 None S-6-1/2 / B-0 4 - Slot CG4SFF6 F6G 1.
CG4 Appliance CL3 Gas Burner Burner Air Tube Beckett Appliance Required Chassis Combination Part # Input BTU Input BTU Part # Head Insertion 140,000 110,000 CG4001 CG4SFF3 F3G 1.75" NG Orifice Size LP Orifice Size Baffle 0.277 0.206 5880 S-7 / B-0 Air Settings Air Band PN / Slot Shutter /Band Number Blank CL4 175,000 160,000 CG4001 CG4SFF4 F4G 1.75" 0.348 0.246 None S-6-1/2 / B-0 4 - Slot CL5 245,000 220,000 CG4001 CG4SFF6 F6G 1.75" 0.422 0.
CG4 Gas Burner Slant/Fin Intrepid Appliance Burner Air Tube Beckett Appliance Required Chassis Combination Part # Input BTU Input BTU Part # Head Insertion NG Orifice Size LP Orifice Size Baffle Air Settings Air Band PN / Slot Shutter /Band Number TR-30 140,000 140,000 CG4001 CG4SFF3 F3G 1.75" None 0.242 None S-8 / B-0 4 - slot TR-40 210,000 190,000 CG4001 CG4SFF4 F4G 1.75" None 0.
Contractor Start-Up Form Installation Name:_________________________________________ Installation Date:___________________ Installation Address:_________________________________________________________________________ Start-Up Contractor’s Name_________________________________ Phone:__________________________ Name of Technician_________________________________________________________________________ ■■ Appliance (Information below can be obtained from appliance name plate) Manufacturer:________________
Notes 10
Limited Warranty Information The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who purchase its “Products” from Beckett for resale, or for incorporation into a product for resale (“Customers”), that its equipment is free from defects in material and workmanship. To qualify for warranty benefits, products must be installed by a qualified service agency in full compliance with all codes and authorities having jurisdiction, and used within the tolerances of Beckett’s defined product specifications.