Boiler Guide

Basic Burner Setup Information Additional Information
Appliance
Model
Low Fire
Rate Baffle
Std. Air
Tube
Pump
Pressure
Recom.
Chassis
Approximate
Air Settings*
Insertion
Depth
Burner
Type
Head
Type
Static Plate/
Stop Screw
Nozzle
Type
Notes
Utica Boiler (contd)
TRB6130 AFG V1-0 2-3/4” 1.10 X 60°AS AFG70MKAQN 140 B2007 S-5 / B-4 2-5/8” 3, 9
TRB6145 AFG V1-2 2-3/4”M 1.10 X 60°AS AFG70MKAQN 175 B2007 S-5 / B-3 2-5/8” 9
TRB7165 AFG V1-2 2-3/4”M 1.25 X 45°AS AFG70MKAQN 175 B2007 S-7 / B-4 2-5/8” 3, 9
SW5 AFII 150 AF2-6 # 8 1.10 X 45°B (H) HLX70HB 140 B7203 5 2-1/4” 15, 31
SFH365 AFII 85 AF2-6 # 2 0.60 X 45°B HLX70HD 140 B7703 2 2-1/4”
SFH6225W CF375 SL1-0 2.00 X 45°B CF100KZ 140 BCF3907 S-6 / B-3 2-1/4”
SFH7275W CF375 SL1-1 2.25 X 45°B CF100KZ 140 BCF3907 S-4 / B-5 2-1/4”
TRB4075DV NX 6-slot 0.60 X 60°B NX70LC 150 B8001 1.5 2-1/2”
TRB4095DV NX 6-slot 0.75 X 60°B (H) NX70LC 155 B8001 4 2-1/2” 31
TRB5100DV NX 6-slot 0.75 X 45°B NX70LC 175 B8001 4 2-1/2”
TRB5115DV NX 6-slot 1.00 X 60°B (H) NX70LF 140 B8001 1.75 2-1/2” 31
TRB5135DV NX 6-slot 1.10 X 60°B NX70LF 150 B8001 2.5 2-1/2”
TRB6130DV NX 9-slot 1.00 X 45°B NX70LD 175 B8001 2.25 2”
ACE7 SM F160 3-3/8” 2.25 X 70°S SM53SC 100
BOP77 SM F223 NONE 2.25 X 60°H SM72SX 100 S-6 / B-0 5”
(3) Pre/post-purge control must be used.
(9) Electrode settings of 1/4” above center of nozzle, 1/8” in front of nozzle and gap 5/32”.
(15) Must maintain 6° downward pitch on air tube/flange.
(31) The (H) in the Nozzle Description denotes a Hago.
(45) Must maintain 4° downward pitch on air tube/flange.
Vaillant
F70-40 AFG F3 3-1/2” 0.65 X 80°B AF65ZP 140 B2008 S-8 / B-0
F70-40 AFG L1 3-3/8” 0.65 X 60°A AFG50MB 140 B2007
F70-45 AFG F3 3-1/2” 0.75 X 80°B AF65ZP 140 B2008 S-8 / B-0
F70-45 AFG L1 3-3/8” 0.65 X 60°A AFG50MB 140 B2007
F70-50 AFG F3 3-1/2” 0.90 X 80°B AF65ZP 140 B2008 S-8 / B-0
F70-50 AFG V1-0 2-3/4” 0.90 X 60°A AFG50MD 140 B2007
F70-55 AFG F6 2-3/4” 1.10 X 80°B AF65YB 140 B2008 S-8 / B-0
F70-55 AFG V1-0 2-3/4” 1.10 X 60°B AFG50MD 140 B2007
F70-60 AFG F6 2-3/4” 1.20 X 80°B AF65YB 140 B2008 S-8 / B-0
F70-60 AFG V1-2 2-3/4” 1.20 X 60°B AFG50MD 140 B2007
F75-40 AFG F3 3-1/2” 0.65 X 80°B AF65ZP 140 B2008 S-8 / B-0
F75-40 AFG L1 3-3/8” 0.65 X 60°A AFG50MB 140 B2007
F75-45 AFG F3 3-1/2” 0.75 X 80°B AF65ZP 140 B2008 S-8 / B-0
F75-45 AFG L1 3-3/8” 0.75 X 60°A AFG50MB 140 B2007
F75-50 AFG F3 3-1/2” 0.90 X 80°B AF65ZP 140 B2008 S-8 / B-0
F75-50 AFG V1-0 2-3/4” 0.90 X 60°A AFG50MD 140 B2007
F75-55 AFG F6 2-3/4” 1.10 X 80°B AF65YB 140 B2008 S-8 / B-0
F75-55 AFG V1-0 2-3/4” 1.10 X 60°B AFG50MD 140 B2007
F75-60 AFG F6 2-3/4” 1.20 X 80°B AF65YB 140 B2008 S-8 / B-0
F75-60 AFG V1-2 2-3/4” 1.20 X 60°B AFG50MD 140 B2007
F100-HE30 AFII 150 AF2-6 # 0 0.50 X 70°B HLX70HB 140 B7210 20
F100-HE35 AFII 150 AF2-6 # 0 0.75 X 70°B HLX70HB 140 B7210 20
F100-HE35 AFII 150 AF2-9 # 0 0.70 X 70°B HLX50HC 140 B7210 3-1/2”
F100-HE40 AFII 150 AF2-6 # 0 0.75 X 70°B HLX70HB 140 B7210 20
F100-HE40 AFII 150 AF2-9 # 0 0.75 X 70°B HLX50HC 140 B7210 3-1/2”
F100-HE45 AFII 150 AF2-6 # 8 1.25 X 60°B HLX70HB 140 B7210 20
F100-HE45 AFII 150 AF2-9 # 6 1.10 X 60°B HLX50HC 140 B7210 3-1/2”
F100-HE50 AFII 150 AF2-9 # 5 1.25 X 60°B HLX50HC 140 B7210
F100-HE50 AFII 150 AF2-6 # 8 1.25 X 60°B HLX70HB 140 B7210 20
F70-40 AFII 150 AF2-6 # 0 0.60 X 70°B HLX 70HD 140 B7210
94