Boiler Guide

Basic Burner Setup Information Additional Information
Appliance
Model
Low Fire
Rate Baffle
Std. Air
Tube
Pump
Pressure
Recom.
Chassis
Approximate
Air Settings*
Insertion
Depth
Burner
Type
Head
Type
Static Plate/
Stop Screw
Nozzle
Type
Notes
New Yorker (contd)
OS-123-1 AFG F6 3-3/8” 1.10 X 80°A AF62YY 100 B2007
OS-140-1 AFG F6 3-3/8” 1.25 X 80°A AF62YY 100 B2007
OS-161-1 AFG F6 3-3/8” 1.50 X 80°A AF62YY 100 B2007
OS-191-1 AFG F12 2-3/4” 1.75 X 80°A AF62XO 100 B2007
PH-176 AFG F6 3-3/8” 1.50 X 80°A AF62YY 100 B2007
PH-203 AFG F12 2-3/4” 1.75 X 80°A AF62XO 100 B2007
S-118-AP AFG F4 3-3/8” 0.85 X 80°B (H) AF40BZ 140 B2007 31
S-131-AP AFG F4 3-3/8” R 1.00 X 80°B (H) AF40BZ 140 B2007 S-10 / B-2 1” 31
S-154-AP AFG F4 3-3/8” R 1.10 X 80°B (H) AF40BZ 140 B2007 S-8 / B-0 1” 31
S-176-AP AFG F6 3-3/8” R 1.25 X 80°B (H) AF40WN 140 B2007 S-10 / B-3 1” 31
S-203-AP AFG F12 2-3/4” 1.50 X 80°B AF40XO 140 B2007 S-10 / B-2 1”
S-97-AP AFG F6 3-3/8” R 0.75 X 80°B (H) AF40WN 140 B2007 S-7 / B-0 1” 31
WH-176 AFG F6 3-3/8” R 1.25 X 80°B (H) AF40WN 140 B2007 S-10 / B-3 1” 31
MICROTEK III
(D.V.I.) AFII 150 AF2-9 # 3 0.85 X 60°B HLX50HE 140 B7210 4 2” 5,6
MICROTEK III
(D.V.I.) AFII 150 AF2-9 # 5 1.00 X 60°B HLX50HE 140 B7210 4 2” 5,6
MICROTEK III
(D.V.I.) AFII 85 AF2-6 # 2 0.50 X 70°B HLX50HD 140 B7711 2 2” 5,6
CI-HGS-127B/DV NX 9-Slot 0.85 X 60°B(H) NX70LB 150 B8001 2.75 2” 31
CI-HGS-176B/DV NX 9-Slot 1.00 X 45°B(H) NX90LD 180 B8001 1 3-1/2” 31
AP-1070 SF F220 2-3/4” 2.50 X 80°B SF56FZ 100 B711 S-4 / B-0 3-5/8”
AP-1170 SF F220 2-3/4” 3.00 X 80°B SF56FZ 100 B711 S-5 / B-0 3-5/8”
CPH-284 SF F220 2-3/4” 2.50 X 80°B SF56FZ 100 B711 S-4 / B-0 3-5/8”
CPH-339 SF F220 2-3/4” 3.00 X 80°B SF56FZ 100 B711 S-5 / B-0 3-5/8”
CPH-396 SF F300 NONE 4.00 X 80°B SF56SA 100 B711 S-5 / B-0 3-5/8”
FD-252 SF F220 2-3/4” 2.50 X 80°B SF56FZ 100 B711 S-5 / B-0 3-5/8”
FD-252 SF F163 2-3/4” 2.50 X 80°B SF56FE 100 B711
FD-330 SF F220 NONE 3.00 X 80°B SF56FD 100 B711
FD-396 SF F300 NONE 4.00 X 80°B SF56SA 100 B711
FD-453 SF F300 NONE 4.50 X 80°B SF56SA 100 B711 S-5 / B-2 3-5/8”
FR-265 SF F220 NONE 2.00 X 80°B SF56FD 140 B711 S-5 / B-0 3-5/8”
FR-305 SF F220 NONE 2.25 X 80°B SF56FD 140 B711 S-5 / B-2 3-5/8”
FR-350 SF F220 NONE 3.00 X 80°B SF56FD 100 B711 S-5 / B-3 3-5/8”
FR-400 SF F220 NONE 3.50 X 80°B SF56FD 100 B711 S-5 / B-3 3-5/8”
FR-462 SF F300 NONE 4.00 X 80°B SF56SA 100 B711 S-5 / B-2 3-5/8”
OS-227-1 SF F220 2-3/4” 2.00 X 80°B SF56FZ 100 B711
OS-270-1 SF F220 2-3/4” 2.50 X 80°B SF56FZ 100 B711 S-5 / B-2
PH-284 SF F220 2-3/4” 2.50 X 80°B SF56FZ 100 B711
PH-339 SF F220 2-3/4” 3.00 X 80°B SF56FZ 100 B711
S-284-AP SF F220 2-3/4” 2.50 X 80°B SF56FZ 100 B711
S-339-AP SF F220 2-3/4” 3.00 X 80°B SF56FZ 100 B711
WH-284 SF F220 2-3/4” 2.50 X 80°B SF56FZ 100 B711
WH-339 SF F220 2-3/4” 3.00 X 80°B SF56FZ 100 B711
WH-396 SF F300 NONE 4.00 X 80°B SF56SA 100 B711
(5) Non-delay valve required.
(6) Nozzle line heater required.
(31) The (H) in the Nozzle Description denotes a Hago.
(39) The AB in the Nozzle Description denotes a Danfoss.
66