Boiler Guide

Basic Burner Setup Information Additional Information
Appliance
Model
Low Fire
Rate Baffle
Std. Air
Tube
Pump
Pressure
Recom.
Chassis
Approximate
Air Settings*
Insertion
Depth
Burner
Type
Head
Type
Static Plate/
Stop Screw
Nozzle
Type
Notes
Grimsby Stove & Furnace Limited
OHG-089/117 AF F3 2-3/4” 0.85 X 70°W AF53XNHS 100 B3001 2
OHG-089/117 AF F3 2-3/4” 0.75 X 70°W AF53XNHS 100 B3001 2
OHG-089/117 AF F3 2-3/4” 1.00 X 70°W AF53XNHS 100 B3001 S-7 / B-0 2
OLF AF F3 2-3/4” 0.85 X 70°W AF53XNHS 100 B3001 2
OLF AF F3 2-3/4” 0.75 X 70°W AF53XNHS 100 B3001 2
OLF AF F3 2-3/4” 1.00 X 70°W AF53XNHS 100 B3001 S-7 / B-0 2
OLG-058/069 AF F3 2-3/4” 0.60 X 70/80°W AF72XNHS 100 B3001 2
OLG-058/069 AF F3 2-3/4” 0.50 X 70/80°W AF72XNHS 100 B3001 2
OLG-058/086 AF F3 2-3/4” 0.75 X 70/80°W AF72XNHS 100 B3001 2
OLG-058/086 AF F3 2-3/4” 0.60 X 70/80°W AF72XNHS 100 B3001 2
OLG-058/086 AF F3 2-3/4” 0.50 X 70/80°W AF72XNHS 100 B3001 2
OLG-058/086 AF F3 2-3/4” 0.65 X 70/80°W AF72XNHS 100 B3001 2
OLG-075/086 AF F3 2-3/4” 0.75 X 70/80°W AF72XNHS 100 B3001 2
OLG-075/086 AF F3 2-3/4” 0.65 X 70/80°W AF72XNHS 100 B3001 2
OLG-080/093 AF F3 2-3/4” 0.75 X 70/80°W AF72XNHS 100 B3001 2
OLG-080/093 AF F3 2-3/4” 0.85 X 70/80°W AF72XNHS 100 B3001 2
OLG-080/122 AF F3 2-3/4” 0.65 X 70/80°W AF72XNHS 100 B3001 2
OLG-080/122 AF F3 2-3/4” 0.75 X 70/80°W AF72XNHS 100 B3001 2
OLG-080/122 AF F3 2-3/4” 0.85 X 70/80°W AF72XNHS 100 B3001 2
OLG-080/122 AF F3 2-3/4” 1.00 X 70/80°W AF72XNHS 100 B3001 2
OLG-105/122 AF F3 2-3/4” 0.85 X 70/80°W AF72XNHS 100 B3001 2
OLG-105/122 AF F3 2-3/4” 1.00 X 70/80°W AF72XNHS 100 B3001 2
OLG-123/144 AF F6 2-3/4” 1.20 X 70/80°W AF72YB 100 B3001
OLG-123/144 AF F6 2-3/4” 1.00 X 70/80°W AF72YB 100 B3001
OLG-123/144 AF F6 2-3/4” 1.10 X 70/80°W AF72YB 100 B3001
OLG-146/162 AF F6 2-3/4” 1.20 X 70/80°W AF72YB 100 B3001
OLG-146/162 AF F6 2-3/4” 1.35 X 70/80°W AF72YB 100 B3001
OLG-146/162 AF F6 2-3/4” 1.25 X 70/80°W AF72YB 100 B3001
OHG-089/117 SV AFII 150 FB3 0.85 X 60°W FBX70HGXS 140 B7203
OHG-089/117 SV AFII 150 FB3 0.75 X 60°W FBX70HGXS 140 B7203
OHG-089/117 SV AFII 150 FB3 0.65 X 60°W FBX70HGXS 140 B7203
OLF AFII 150 FB3 0.75 X 60°W FBX70HGXS 140 B7203
OLF AFII 150 FB3 0.85 X 60°W FBX70HGXS 140 B7203
OLF AFII 150 FB3 0.65 X 60°W FBX70HGXS 140 B7203
(2) “HS” on air tube combination = ceramic heat shield on combustion head.
GSW
JWF307 (CANADA) AF F3 3-3/8” 0.65 X 70°A AF65YH 100 B3001 S-4 / B-0 4-3/4”
JW317/327 AFG F3 3-3/8”R 0.75 X 80°A AF90BN 100 B2007 S-6 / B-0 7” 12
JW317/327 (U.S.) AFG F3 3-3/8”R 0.75 X 80°A AF90BN 100 B2007 S-6 / B-0 7”
JW517/527 AFG F3 3-3/8”R 0.85 X 80°A AF90BN 100 B2007 S-6 / B-0 7” 12
JW517/527 (U.S.) AFG F3 3-3/8”R 0.85 X 80°A AF90BN 100 B2007 S-6 / B-0 7”
JW717/727 AFG F3 3-3/8”R 1.00 X 80°A AF90BN 100 B2007 S-6 / B-0 12
JW717/727 (U.S.) AFG F3 3-3/8”R 1.00 X 80°A AF90BN 100 B2007 S-6 / B-0
JWF307 AFG F0 2-3/4” 0.75 X 80°A 5880 AF65XZT 100 B2007 12
47