Boiler Guide
Basic Burner Setup Information Additional Information
Appliance
Model
Low Fire
Rate Baffle
Std. Air
Tube
Pump
Pressure
Recom.
Chassis
Approximate
Air Settings*
Insertion
Depth
Burner
Type
Head
Type
Static Plate/
Stop Screw
Nozzle
Type
Notes
Peerless Heater (cont’d)
HEO-4L AFG F6 2-3/4” 1.25 X 70°B — AF44YB 100 B2007 — —
HEO-5H AFG F16 2-3/4” 2.00 X 70°B — AF44WF 100 B2007 — —
HEO-5L AFG F16 2-3/4” 1.75 X 70°B — AF44WF 100 B2007 — —
JO/JOT-TW100 AFG F3 3-3/8” 0.85 X 80°A — AF60YH 140 B2007 — —
JO/JOT-TW125 AFG F3 3-3/8” 1.10 X 80°B — AF60YH 140 B2007 — —
JO/JOT-TW150 AFG F6 2-3/4” 1.25 X 80°A — AF60YB 140 B2007 S-8 / B-1 —
JO/JOT-TW175 AFG F6 2-3/4” 1.50 X 80°A — AF60YB 140 B2007 — —
JO/JOT-TW200 AFG V1-4 2-3/4” 1.75 X 70°B — AFG50MD 140 B2007 — —
JO/JOT-TW250 AFG V1-5 2-3/4” 2.00 X 70°B — AFG50MD 140 B2007 — —
JO/JOT-TWO75 AFG F3 3-3/8” 0.65 X 80°A 5880 AF60YH 140 B2007 — —
PO-50 AFG L2 3-3/8” 0.45 X 60°AS — AFG70MQASN 130 B2007 — 3” 9, 16
PO-60 AFG L2 3-3/8” 0.55 X 60°AS — AFG70MQASN 130 B2007 2 3” 9, 16
PRO-04-100 AFG L1 2-3/4” 0.85 X 60°A — AFG70MTAQN 140 B2007 S-10 / B-2 4”
9,16,40
PRO-05-100 AFG L1 NONE 0.75 X 45°B — AFG70MNASN 190 B2007 S-7 / B-1 4” 9, 40
PRO-05-125 AFG L1 NONE 0.90 X 60°B — AFG70MNASN 190 B2007 S-10 / B-3 4” 9, 40
PRO-03 AFG L2 3-3/8” 0.50 X 60°AS 5880 AFG70MQASN 140 B2007 S-4 / B-0 3-3/4”
9,16,45
PRO-04-80 AFG L1 2-3/4” 0.65 X 60°A — AFG70MTAQN 140 B2007 S-7 / B-0 4”
9,16,40
WBV-03-085 AFG F3 3-3/8” 0.75 X 80°B (H) 5880 AF60YH 140 B2007 — — 31
WBV-03-110 AFG F4 3-3/8” 0.90 X 80°B (H) — AF60WP 140 B2007 S-6 / B-0 2-1/2” 31
WBV-04-125 AFG F4 3-3/8” 1.10 X 80°B (H) — AF60WP 140 B2007 S-8 / B-2 2-1/2” 31
WBV-04-150 AFG F6 2-3/4” 1.25 X 80°A — AF60YB 140 B2007 S-8 / B-1 —
WV-05-175 AFG F12 NONE 1.50 X 80°B (H) — AF72YN 140 B2007 — 2-9/16” 31
WV-05-175 AFG V1-3 NONE 1.50 X 60°B (H) — AFG70ML 140 B2007 — 2-9/16” 31
WV-05-200 AFG V1-4 NONE 1.75 X 60°B (H) — AFG70ML 140 B2007 — 2-9/16” 31
WV-05-200 AFG F16 NONE 1.75 X 70°B (H) — AF72WK 140 B2007 — 2-9/16” 31
WV-DV-03-075 AFII100 AF2-6 # 3 0.60 X 70°B — HLX50HB 170 — — —
WV-DV-03-085 AFII100 AF2-6 # 4 0.65 X 45°B (H) — HLX50HB 170 — — — 31
WV-DV-03-110 AFII100 AF2-6 # 6 0.85 X 60°B — HLX50HB 170 — — 2-1/2”
WBV-03-060 NX 6-slot — 0.50 X 60°W 32229 NX70LC 140 B8001 1.5 2-1/2”
WBV-03-085 NX 9-slot — 0.65 X 60°W — NX70LB 175 B8001 2.5 2-1/2”
WBV-04-095 NX 6-slot — 0.85 X 60°B — NX70LC 140 B8001 2.75 2-1/2”
WBV-04-125 NX 9-slot — 1.10 X 60°W — NX70LD 140 B8001 1.25 2”
WBV-04-150 NX 9-slot — 1.25 X 60°W — NX70LD 140 B8001 2.25 2”
WBV-03-1.10 NX 9-slot — 0.85 X 60°B (H) — NX70LB 175 B8001 3.75 2-1/2” 31
WV-DV-03-0.85 NX 9-slot — 0.65 X 60°W 32229 NX70LB 175 B8001 3 2-1/2” 3
WV-DV-04-1.15 NX 9-slot — 0.85 X 60°B (H) 32229 NX70LD 170 B8001 1.5 2-1/2” 31
JO/JOT-TW275 SF F220 2-1/4” 2.25 X 70°B — SF44VT 140 B711 — —
JO/JOT-TW300 SF F220 2-1/4” 2.50 X 70°B — SF44VT 140 B711 — —
(3) Pre/post-purge control must be used.
(9) Electrode settings of 1/4” above center of nozzle, 1/8” in front of nozzle and gap 5/32”.
(16) With conic shroud, “Z” dimension is 1-3/4”.
(31) The (H) in the Nozzle Description denotes a Hago.
(40) Must maintain 0° downward pitch on air tube/flange.
(45) Must maintain 4° downward pitch on air tube/flange.
75