Includes: Burner Chassis, Basic Burner Setup Information, Air Tube Combinations For Wholesalers & Ser ervic vicee Technicia T chnicians ns
The Wholesaler’s & Service Technician’s Guide to OEM Residential Oil Specifications INTRODUCTION WARNING Only personnel specifically trained and equipped with the proper tools to service oil burning equipment should attempt adjustments or repair of equipment. Improper adjustment of any gas or oil burning equipment can create smoke, carbon monoxide or a fire, which can cause injury or death to the building occupants.
Table of Contents Instructions for Using the Beckett Service Hotline . . . . . . . . . . . . . . . . . . IFC Enterprise Fawcett . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Peerless Heater . . . . . . . . . . . . . . . . . . . . . . . . . . 74-75 Evcon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43-44 Pennco . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Instructions for Using the Beckett OEM Specification Guide 1. For your convenience, this guide is arranged in alphabetical order by manufacturer. 2. Locate OEM name. 3. Locate Appliance Model Number. 4. Locate Burner Type (AF, AFG, SF...). 5. Locate Air Tube Combination. This will include: A. Burner Model B. Air Tube Length C. Head Type D. Static Plate E. Special Construction. (See example below.) 6. To identify the Special Construction Codes, turn to the Air Tube Combination Code Listing pages. 7.
R.W. Beckett Air Tube Combination Code Listing A.T.C.
R.W. Beckett Air Tube Combination Code Listing A.T.C.
R.W. Beckett Air Tube Combination Code Listing A.T.C. Code Burner Head Static Plate A.T.C.
Footnotes Note Number Note 1 “FS” on air tube combination = fiber heat shield on combustion head. 2 “HS” on air tube combination = ceramic heat shield on combustion head. 3 Pre/post-purge control must be used. 4 Requires delay solenoid valve. 5 Non-delay valve required. 6 Nozzle line heater required. 7 D1 head requires 7/8” “Z” dimension. 8 2-slot air band 31840BK required. 9 Electrode settings of 1/4” above center of nozzle, 1/8” in front of nozzle and gap 5/32”.
Footnotes Continued Note Number 6 Note 41 Must maintain 0.5° downward pitch on air tube/flange. 42 Must maintain 1° downward pitch on air tube/flange. 43 Must maintain 1.5° downward pitch on air tube/flange. 44 Must maintain 2.5° downward pitch on air tube/flange. 45 Must maintain 4° downward pitch on air tube/flange. 46 Must maintain -2° upward pitch on air tube/flange. 47 Must utilize blanket kit 8”x17”, P.N. 32408. 48 "MR" air tube combination uses CF375 electrode kit 51858.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw 140MBTU AF F3 2-3/4” 199MBTU AF F6 2-3/4” 270MBTU AF F12 Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth 1.00 X 80°B — AF65XN 100 B3001 — — 1.35 X 80°B — AF65YB 100 B3001 — — 2-3/4” 2.00 X 80°B — AF65XO 100 B3001 — — Notes A.O. Smith 400MBTU AF F31 NONE 2.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Adams \ Dornback (cont’d) ACOV-230 AFG F22 2-3/4” 1.35 X 70°A — AF72XP 140 B2007 — — ACOV-350 AFG F31 NONE 2.00 X 70°A — AF72XS 140 B2007 — — OCF-105 AFG F3 2-3/4” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes 31 Advantage / Pure Pro / Trio AO(T)-3 / 0.65 AFG L1 3-3/8” 0.55 X 60°B(H) 5880 AFG70MBAS 140 B2007 S-5 / B-1 2-1/4” AO(T)-3 / 0.75 AFG L1 3-3/8” 0.65 X 60°B(H) 5880 AFG70MBAS 140 B2007 S-10 / B-2 2-1/4” 31 AO(T)-3 / 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes 27 American Standard (cont’d) ADF1M087A936-948SAA AF F3 2-3/4” 0.85 X 80°A — AF57XNSS 130 B3001 — — ADF1M087A936-948SAA AF F3 2-3/4” 1.00 X 80°A — AF57XNSS 130 B3001 — — 27 ADF1M087A9V3-9V5SAA AF F3 2-3/4” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes ARCO Air / Comfortmaker / ICP OCH055A012 AFG F3 3-3/8” 0.50 X 80°S 5880 AF47YHFS 100 B2007 — — 1 OCH075A012 AFG F3 3-3/8” 0.75 X 70°H 5880 AF47YHFS 100 B2007 — — 1 OCH100A016 AFG F3 3-3/8” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Armstrong / Air Ease (cont’d) 12 L5BR140/168 AFG F6 2-3/4” 1.50 X 80°B — AF55YB 100 B2007 — — L5BR140DC20 AFG F6 2-3/4” 1.25 X 80°B — AF55YB 100 B2007 — — L5BR168DC20 AFG F6 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Armstrong / Air Ease (cont’d) LBR80C112/125B16-1 AFG F6 2-3/4” 0.85 X 80°B — AF50YB 140 B2007 S-6 / B-1 — LBR80C112/125D20-1 AFG F6 2-3/4” 0.85 X 80°B — AF50YB 140 B2007 S-6 / B-1 — LBR80C140/168D20-1 AFG F6 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes 23 Armstrong / Air Ease (cont’d) L5A-84 AR R4 3-3/8” 0.75 X 80°S — AR53XL 100 B3001 — — L5A-95 AR R4 3-3/8” 0.85 X 80°S — AR53XL 100 B3001 — — 23 L62-112 AR R4 3-3/8” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Axeman-Anderson (cont’d) 87POU-2 AF F3 2-3/4” 0.85 X 80°B — AF44XN 100 B3001 — — A,EA113W AF F6 2-3/4” 1.35 X 80°A — AF60YB 100 B3001 — — A,EA139W AF F6 2-3/4” 1.65 X 80°B — AF60YB 100 B3001 — — A,EA165W AF F16 NONE 2.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Axeman-Anderson (cont’d) (37) AQ in ATC designates 16-slot venturi. (45) Must maintain 4° downward pitch on air tube/flange. Bard Manufacturing 16 0L140B48A AF F12 2-3/4” 1.25 X 80°S — AF65XO 100 B3001 — — 0L196B60A AF F12 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Bard Manufacturing (cont’d) 0L95B36A AR R4 2-3/4” 0.85 X 80°S — AR53XZ 100 B3001 — — 23 0S125D48A AR R4 2-3/4” 1.10 X 80°S — AR53XZ 100 B3001 — — 23 0S95D36A AR R4 2-3/4” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Benjamin Htg. Products (cont’d) OB1000-B120 AFII 150 AF2-9 #0 0.85 X 60°B — HLX50HC 140 B7203 6 2-3/4” OB1000-B150 AFII 150 AF2-9 #5 1.00 X 60°B — HLX50HC 140 B7203 4 2-3/4” OB1000-B180 AFII 150 AF2-9 #8 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes 3 Biasi / Neca / Vega / QHT (cont’d) SG35 – D.V. AFII 150 AF2-9 #2 0.85 X 60°B — HLX70HC 140 B7210 5 5” SG46 AFII 150 AF2-6 #7 1.00 X 60°B — HLX70HD 160 B7203 5 5” SG46 – D.V. AFII 150 AF2-6 #7 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Borg-Warner (cont’d) P3HFD17F08501A AFG F3H 3-3/8” 0.75 X 70°A 5880 AF47YTSS 100 B2007 S-7 / B-0 4-7/8” 27 P3HFD17F10001A AFG F3H 3-3/8” 0.90 X 70°A 5880 AF47YTSS 100 B2007 S-8 / B-0 4-7/8” 27 P3LFB17F12501A AFG F6H 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Boyertown Furnace / Hallmark / Regal (cont’d) LB85 AFG F3 3-3/8” 0.65 X 80°A 5880 AF90YH 140 B2007 S-7 / B-0 5-5/8” 2 REGAL 1250 AFG F6 2-3/4” 1.25 X 80°B — AF90YBHSSS 100 B2007 S-9 / B-0 7-3/4” 2, 27 REGAL 600 AFG F3 3-3/8” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Brock Engineering (cont’d) CCC AFG F3 2-3/4” 0.65 X 80°W — AF65XN 100 B2007 — — CCC AFG F3 2-3/4” 0.85 X 80°W — AF65XN 100 B2007 — — IB-30 AFG F0 3-3/8” 0.60 X 80°W — AF65XR 100 B2007 — — MBT AFG F3 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes 40 Buderus (cont’d) G-215-3 AFG V1-0 NONE 0.90 X 45°ES — AFG50ML 170 B2007 S-8 / B-0 3-1/2” G-215-4 AFG V1-2 NONE 1.10 X 45°ES — AFG50ML 175 B2007 S-8 / B-2 3-1/2” 40 G-215-5 CF375 V1-2 — 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Burnham (cont’d) 24 MST288 AFG L1 3-3/8” 0.60 X 60°A 5880 AFG70MMAQN 150 B2007 S-6 / B-1 2” 9, 16 MST396 AFG L1 3-3/8” 0.85 X 60°B — AFG70MMAQN 150 B2007 S-7 / B-1 2” 9,16, 51 9,16, 52 MST396 AFG L1 3-3/8” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes 31 Burnham (cont’d) V-78 AFG V1-5 2-3/4” 2.00 X 45°P (H) — AFG50MD 140 B2007 S-10 / B-5 1-11/16” V-79 AFG V1-6 2-3/4” 2.25 X 45°P (H) — AFG50MD 140 B2007 S-10 / B-7 1-11/16” 31 V-82 AFG L1 3-3/8” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Carrier Corp. 26 388EAN048085 AFG F3H 3-3/8” 0.75 X 70°A 5880 AF47YT 100 B2008 S-8 / B-0 — 388EAN048100 AFG F3H 3-3/8” 0.90 X 70°A 5880 AF47YT 100 B2008 S-8 / B-0 — 388EAP048125 AFG F3H 3-3/8” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth — Notes Carrier Corp (cont’d) 58HM125-JA AFG F3H 3-3/8” 1.10 X 70°A 5880 AF47YT 100 B2008 S-8 / B-0 58HM125-LA AFG F3H 3-3/8” 1.10 X 70°A 5880 AF47YT 100 B2008 S-8 / B-0 — 58HM150111CA AFG F6H 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Clare Brothers (cont’d) 28 OLB-503FD AFG F3 3-3/8”R 0.50 X 70°A 5880 AF53BN 100 B2007 — 3-1/4” 29 OLB-503FD AFG F3 3-3/8”R 0.75 X 70°A — AF53BN 145 B2007 — 3-1/4” 29 OLB-503FD AFG F3 3-3/8”R 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Clare Brothers (cont’d) OLB-F SR F3 2-3/4” 0.85 X 80°A — SR83RD 100 B1025 — — OLB-F SR F3 2-3/4” 0.65 X 80°A — SR83RD 100 B1025 — — OLB-F SR F3 2-3/4” 1.00 X 80°A — SR83RD 100 B1025 — — OLB-R SR F3 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Columbia Boiler Co. (cont’d) EM 100 AFG F3 3-1/2” 0.75 X 80°B — AF56ZP 140 B2008 S-10 / B-0 — EM 110 AFG F6 3-1/2” 0.85 X 80°B — AF56ZG 140 B2008 S-10 / B-0 — EM 125 AFG F6 3-1/2” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Columbia Boiler Co. (cont’d) LV/LVD-110 AFII 150 AF2-9 #3 0.90 X 70°B — HLX70HC 140 B7210 4.25 — LV/LVD-75 AFII 150 AF2-9 #0 0.65 X 70°B — HLX70HC 140 B7210 2 — WB-100 AFII 150 AF2-9 #3 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Cox Mfg. Inc. 32 CFO 115 AF F3 2-3/4” 1.00 X 80°B — AF90XN 100 B3001 — — CFO 150 AF F3 2-3/4” 1.25 X 80°B — AF90XN 100 B3001 — — CFO 225 AF F12 2-3/4” 1.75 X 80°B — AF90XO 100 B3001 — — CFO 80 AF F3 2-3/4” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth — Notes Cox Mfg. Inc. (cont’d) SO 400 SF F310 NONE 3.50 X 80°B — SF90FT 100 B711 — SO 525 SF F310 NONE 4.50 X 80°B — SF90FT 100 B711 — — SO 600 SF F310 NONE 2 - 2.50 X 80°B — SF90FT 100 B711 — — 30 SO 800 SF F310 NONE 2 - 3.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Crown Boiler Co. (cont’d) 34 BD147 AFG V1-0 2-3/4” 1.00 X 70°B — AFG50MDAS 140 B2007 S-8 / B-0 2” BD151 AFG V1-0 2-3/4” 1.10 X 70°B — AFG50MDAS 140 B2007 S-8 / B-0 2” BD178 AFG V1-1 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Crown Boiler Co. (cont’d) CLBF68 NX 9-slot — 0.50 X 60°W 32229 NX70LBHS 150 B8001 2.5 5-3/4” 2 CLBF87 NX 9-slot — 0.60 X 60°W 32229 NX70LBHS 150 B8001 3 5-3/4” 2 CLBF96 NX 9-slot — 0.65 X 60°W 32229 NX70LBHS 150 B8001 3.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes 3,31,40 Dedietrich / Marketing Company of North America (cont’d) GT126A-DV GT204 NX 9-slot — 0.65 X 60°B (H) — NX90LB 175 B8001 2.5 7” SMG SV1-0 — 1.25 X 60°B — SMG82NR 150 — S-6 / B-0 4-1/4” (3) Pre/post-purge control must be used.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Dettson Industries (cont’d) HM 266 AFG V1-3 2-3/4” 2.25 X 70°B — AFG50MD 100 B2007 — — HM 266A AFG F22 2-3/4” 2.25 X 80°B — AF53XP 100 B2007 — — HM 293 AFG V1-4 2-3/4” 2.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Ducane (cont’d) CHZA125D34C1 AFG F6 2-3/4” 1.10 X 70°H 5880 AF67YBFS 100 B2008 S-8 / B-0 — 1 DCFA 085 AFG F3 3-3/8” 0.75 X 70°H 5880 AF47YHFS 100 B2008 S-8 / B-0 — 1 DCFA 100 AFG F3 3-3/8” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Dunkirk Radiator (cont’d) 1362, 136S AF F12 2-3/4” 1.65 X 80°A — AF60XO 100 B3001 — — 136-2,S AF F6 2-3/4” 1.65 X 80°B — AF60YB 100 B3001 — — 1372, 137S AF F12 2-3/4” 2.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Dunkirk Radiator (cont’d) EW 5 AFG V1-0 2-3/4” 1.00 X 60°B — AFG50MD 100 B2007 S-10 / B-5 2-1/4” EW 5 AFG V1-2 2-3/4” 1.50 X 45°B — AFG50MD 100 B2007 S-10 / B-5 2-1/4” EW 5 AFG V1-4 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Elect. Furnace-Man (cont’d) LO-150-4 AF F12 2-3/4” 1.25 X 70°S — AF56XO 100 B3001 — — LO-200—2 AF F12 2-3/4” 1.75 X 70°S — AF56XO 100 B3001 — — OBT-275-C5 AF F31 NONE 2.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Ener Royal Technology 42 EN201 AF F3 2-3/4” * X 70°A — AF65XN 100 B3001 — — 11 EN202 AF F0 3-3/8” * X 70°A — AF53XR 100 B3001 — — 11 ERCF-73 AF F0 3-3/8” 0.65 X 70°A — AF53XR 100 B3001 — — ERCF-84 AF F0 3-3/8” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Ener Royal Technology (cont’d) ERLB95-125SF AFII 150 AF2-9 #5 1.00 X 70°A — HLX90HC 140 B7203 4 — ERLB95-125SF AFII 150 AF2-9 #5 0.85 X 70°A — HLX90HC 140 B7203 4 — ERLB95-125SF AFII 150 AF2-9 #5 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw F6 2-3/4” Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes 5880 AF67YBFS 100 B2008 — — 1 Evcon (cont’d) BOM15420DA AFG 1.10 X 70°H (1) “FS” on air tube combination = fiber heat shield on combustion head. (2) “HS” on air tube combination = ceramic heat shield on combustion head.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Fraser-Johnston (cont'd) PCHFD17F10001 AFG F3H 3-3/8” 0.90 X 70°A 5880 AF47YTSS 100 B2008 — — 27 PCLFB17F12501 AFG F6H 2-3/4” 1.10 X 70°A 5880 AF67JPSS 100 B2008 — — 27 PCLFB20F15001 AFG F6H 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Fraser-Johnston (cont'd) P-FMD16F10001A AFG F3 3-3/8” 0.90 X 70°H 5880 AF47YHFS 100 B2008 — — 1 P-FMD20F10001A AFG F3 3-3/8” 0.90 X 70°H 5880 AF47YHFS 100 B2008 — — 1 P-FMD20F12501A AFG F6 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes 2 Grimsby Stove & Furnace Limited OHG-089/117 AF F3 2-3/4” 0.85 X 70°W — AF53XNHS 100 B3001 — — OHG-089/117 AF F3 2-3/4” 0.75 X 70°W — AF53XNHS 100 B3001 — — 2 OHG-089/117 AF F3 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes 12 GSW (cont'd) JWF307 AFG F0 2-3/4” 0.65 X 80°A 5880 AF65XZT 100 B2007 — — JWF307 (CANADA) AFG F0 2-3/4” 0.65 X 80°A 5880 AF65XZT 100 B2007 S-7 / B-0 4-3/4” JWF307 (U.S.) AFG F0 2-3/4” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes H.B. Smith (cont’d) BB14-4L AFG F6 3-3/8” 1.20 X 80˚A — AF53YY 100 B2007 S-10 / B-1 2-1/4” BB14-4L AFG F6 3-3/8” 1.00 X 80˚A — AF53YY 140 B2007 S-10 / B-4 2-1/4” BB14-5H AFG F16 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Heat Controller / ComfortAir / Century / Patriot (cont’d) OUI 95 50 AF F3 2-3/4” 0.85 X 80°S — AF60XN 100 B3001 — — OAD 084 AFG F3 2-3/4” 0.75 X 80°S 5880 AF60XN 100 B2007 — — OAD 095 AFG F3 2-3/4” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Heat Controller / ComfortAir / Century / Patriot (cont’d) OUFB 125 AFG F4 3-3/8” 0.85 X 80°B — AF46WPHS 140 B2007 S-6 / B-0 5” 2 OUFB 125 AFG F4 3-3/8” 1.00 X 80°B — AF46WPHS 140 B2007 S-9 / B-0 5” 2 OUFB 75 AFG F0 2-3/4” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Hydrotherm, Inc. OR-105 AF F3 3-3/8” 0.75 X 80°A — AF54YH 100 B3001 S-7 / B-0 1-3/8” OR-140 AF F3 3-3/8” 1.00 X 80°A — AF54YH 100 B3001 S-7 / B-0 1-3/8” OR-175 AF F6 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Intertherm (cont'd) 01MA-085C12B AFG F3 3-3/8” 0.75 X 70°H 5880 AF47YHFS 100 B2008 S-7 / B-0 — 1 01MA-100C16B AFG F3 3-3/8” 0.90 X 70°H 5880 AF47YHFS 100 B2008 S-7 / B-0 — 1 01MA-125C20B AFG F6 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Int’l Comfort Prod. / Lincoln Barriere (cont'd) 54 OHB5-F 0.63 AFG F0 2-3/4” 0.50 X 70°A 5880 AF72XZT 155 B2007 S-8 / B-0 5-1/8” OHB5-F 0.75 AFG F0 2-3/4” 0.60 X 70°B — AF72XZT 155 B2007 S-8 / B-0 5-1/8” OHB6-F 0.85 AFG F3 2-3/4” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Int’l Comfort Prod. / Lincoln Barriere (cont'd) OLB5R 0.75 AFII 085 AF2-6 #3 0.60 X 60°W — HLX70HD 155 B7703 4 4-15/16” OLF105 0.50 AFII 085 AF2-6 #3 0.50 X 60°W — HLX70HD 100 B7703 2 4-15/16” OLF105 0.63 AFII 085 AF2-6 #3 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Janitrol (cont’d) UHZB085BK AFG F3 3-3/8” 0.75 X 70°H 5880 AF47YHFS 100 B2008 — — 1 UHZB100BK AFG F3 2-3/8” 0.90 X 70°H 5880 AF47YHFS 100 B2008 — — 1 UHZB125BK AFG F6 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Kerr Heating Products (cont’d) KDFG, KDRG-115 GE AFG L1 3-3/8” 0.75 X 60°B — AFG70MMASN 140 B2007 — 2-1/2” 9,16,40 KDFG, KDRG-115 GE AFG L1 3-3/8” 0.50 X 60°B — AFG70MMASN 140 B2007 — 2-1/2” 9,16,40 KDFG, KDRG-115 GE AFG L1 3-3/8” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes 2 Lennox (cont’d) 58 ELO183UF/150 AFG F4 3-3/8” 1.00 X 80°B — AF46WPHS 140 B2007 S-9 / B-0 5” O20Q3-105/120 AFG F3 2-3/4” 0.85 X 80°B — AF50XN 100 B2007 S-8 / B-0 — O23-175 AFG F6 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw 6-Slot — Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes — NX70LCHS 150 B8001 3.75 5” 55 — Lennox (cont’d) SLO185UF/141 NX 0.85 X 60°A (2) “HS” on air tube combination = ceramic heat shield on combustion head. (23) R4 Head has a 1” “Z” dimension.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Luxaire (cont’d) 60 PCLFB17F12501 AFG F6H 2-3/4” 1.10 X 70°A 5880 AF67JPSS 100 B2008 S-9 / B-1 — 27 PCLFB20F15001 AFG F6H 2-3/4” 1.35 X 70°A — AF67JPSS 100 B2008 S-9 / B-1 — 27 PCLFD12F08501 AFG F3H 3-3/8” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw F12 2-3/4” Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes — AF67XOFS 100 B2008 S-5 / B-2 — 1 Luxaire (cont’d) P-FMD20F17001A AFG 1.50 X 70°S (1) “FS” on air tube combination = fiber heat shield on combustion head. (7) D1 head requires 7/8” “Z” dimension.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Magic Chef (cont’d) L7A-112D AR R4 3-3/8” 1.00 X 80°S — AR53XL 100 B3001 — — 23 L7A-125D AR R4 3-3/8” 1.10 X 80°S — AR53XL 100 B3001 — — 23 L7A-84D AR R4 3-3/8” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Melvin Mfg. Corp. (cont'd) SS4150 AFG V1-1 2-3/4” 1.50 X 70°R — AFG50MD 100 B2007 — — SS4150-99 AFG F6 3-3/8” 1.25 X 80°A — AF44BA 100 B2007 — — SS5120-99 AFG L1 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Metromatic Mfg. Co. (cont'd) SU120 AF F3 2-3/4” 1.00 X 80°A — AF90XN 100 B3001 S-7 / B-0 — SU140 AF F3 2-3/4” 1.25 X 80°A — AF90XN 100 B3001 S-7 / B-0 — SU200 AF F12 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes New Yorker (cont’d) AP-790 AFG F4 3-3/8” R 1.10 X 80°B (H) — AF40BZ 140 B2007 — 1” 31 AP-870 AFG F6 3-3/8” 1.25 X 80°B (H) — AF40WN 140 B2007 S-10 / B-3 1” 31 AP-970 AFG F12 3-3/8” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes New Yorker (cont’d) OS-123-1 AFG F6 3-3/8” 1.10 X 80°A — AF62YY 100 B2007 — — OS-140-1 AFG F6 3-3/8” 1.25 X 80°A — AF62YY 100 B2007 — — OS-161-1 AFG F6 3-3/8” 1.50 X 80°A — AF62YY 100 B2007 — — OS-191-1 AFG F12 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Newmac Mfg. Inc. NH2 AF F3 2-3/4” 1.00 X 80°AR — AF81XN 100 B3001 S-7 / B-0 — NH2 AF F3 2-3/4” 0.85 X 80°AR — AF81XN 100 B3001 S-7 / B-0 — NH2 AF F3 2-3/4” 0.75 X 80°AR — AF81XN 100 B3001 S-7 / B-0 — NH2 AF F3 2-3/4” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Newmac Mfg. Inc. (cont’d) NL3-121 AFG F6 3-3/8” 1.00 X 70°A — AF81YYHSSS 100 B2007 S-10 / B-0 7-13/16” 2, 27, 42 NL3-149 AFG F6 3-3/8” 1.25 X 70°A — AF81YYHSSS 100 B2007 S-10 / B-0 7-13/16” 2, 27, 42 NL3-160 AFG F6 3-3/8” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Nordyne / Miller (cont’d) M1SH-066 AF F3 2-3/4” 0.50 X 80°A — AF33XN 100 B3001 — 2-5/8” 17, 42 M1SH-086 AF F3 2-3/4” 0.65 X 80°A — AF33XN 100 B3001 — 2-5/8” 17, 42 MOC100 AF F3H 2-3/4” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Olsen Technology, Inc. (cont’d) BCL115 (CDN.&U.S.) AF F3 2-3/4” 1.00 X 80°A — AF65XN 100 B3001 S-7 / B-0 — BCL-120S (T) AF F3 2-3/4” 1.00 X 80°A — AF76XN 100 B3001 — — BCL125 (CDN.&U.S.) AF F6 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Olsen Technology, Inc. (cont’d) WML60A/B AF F3 3-3/8” 0.50 X 80°A 5880 AF76BNHS 100 B3001 S-7 / B-0 — 2 WML80A/B AF F3 3-3/8” 0.65 X 80°A — AF76BNHS 100 B3001 S-8 / B-0 — 2 WML90A/B AF F3 3-3/8” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Olsen Technology, Inc. (cont’d) WML-60C NX 6-slot — 0.40 X 70°W 32229 NX90LHHS 150 B8001 2.5 6-9/16” 40, 56 WML-80C NX 6-slot — 0.55 X 60°W 32229 NX90LHHS 140 B8001 3.25 6-9/16” 40, 56 WML-90C NX 6-slot — 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Oneida Royal Heater 0-112 AF F3 2-3/4” 1.00 X 80°B — AF53XN 100 B3001 S-7 / B-0 — 0-140 AF F6 2-3/4” 1.25 X 80°B — AF53YB 100 B3001 S-7 / B-0 — 0-168 AF F6 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type 361AAN036075 AFG F3 3-3/8” 361AAN036105 AFG F3 3-3/8” 361AAN048125 AFG F3 3-3/8” 361AAN060155 AFG F6 2-3/4” 1.10 X 70°H 362AAN036075 AFG F3 3-3/8” 0.50 X 80°S 362AAN036105 AFG F3 3-3/8” 0.75 X 70°H 362AAN048125 AFG F3 3-3/8” 362AAN060155 AFG F6 2-3/4” Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Peerless Heater (cont’d) HEO-4L AFG F6 2-3/4” 1.25 X 70°B — AF44YB 100 B2007 — — HEO-5H AFG F16 2-3/4” 2.00 X 70°B — AF44WF 100 B2007 — — HEO-5L AFG F16 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Pennco 1304 AF F3 2-3/4” 1.00 X 80°A — AF60XN 100 B3001 — — 1305 AF F12 2-3/4” 1.35 X 80°A — AF60XO 100 B3001 — — 1306 AF F12 2-3/4” 1.65 X 80°A — AF60XO 100 B3001 — — 1307 AF F12 2-3/4” 2.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Pow-R-Matic, Inc. CA-20 AF F12 2-3/4” 1.75 X 80°A — AF72XO 100 B3001 — — CA-25 AF F31 2-3/4” 2.25 X 80°A — AF72XS 100 B3001 — — CA-30 AF F31 2-3/4” 2.75 X 80°A — AF72XS 100 B3001 — — UH100 AF F3 2-3/4” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Rheem Manufacturing (cont’d) 78 ROMB-120 AF F3 2-3/4” 1.10 X 70°S — AF60XN 100 B3001 S-7 / B-0 — ROMB-130 AF F12 2-3/4” 1.20 X 80°S — AF60XO 100 B3001 S-7 / B-0 — ROMB-150 AF F12 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Rheem Manufacturing (cont’d) ROUC-095 AFG F3 3-3/8”R 0.85 X 70°S — AF36BN 100 B2007 S-7 / B-0 — 50 ROUC-112 AFG F3 2-3/4” 1.00 X 70°S — AF36XN 100 B2007 S-7 / B-0 — 50 ROUC-130 AFG F6 3-3/8”R 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes 50 Ruud (cont’d) UOBC 056 AFG F0 3-3/8”R 0.50 X 70°R — AF36JY 100 B2007 S-7 / B-0 — UOBC 067 AFG F0 3-5/8” 0.60 X 70°AR — AF36YL 100 B2007 S-7 / B-0 — 50 UOBC 067 AFG F0 3-3/8”R 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Siebring Mfg. Co. (cont’d) QUANTUM 140 AFG F4 3-3/8” 1.00 X 80°B — AF65WH 100 B2007 S-7 / B-0 5” QUANTUM 210 AFG F16 2-3/4” 1.50 X 80°A — AF65WF 100 B2007 S-10 / B-0 5” TH150 AFG F4 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes 2 Spirit (cont’d) VHF-ABE-90 NX 9-slot — 0.60 X 70°A 32229 NX50LGHS 150 B8001 2.75 4-1/2” VHF-ABP-60 NX 9-slot — 0.40 X 70°A 32229 NX50LGHS 150 B8001 2 4-1/2” 2 VHF-ABP-72 NX 9-slot — 0.50 X 70°A 32229 NX50LGHS 150 B8001 2.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Tekton Corp. Z020 AFG F12 2-3/4” 1.50 X 80°A — AF65XO 100 B2007 S-7 / B-0 4-7/8” Z040 AFG F31 2-3/4” 2.75 X 80°B — AF65XV 100 B2007 S-7 / B-0 4-7/8” OT35 AF F3 3-3/8” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Thermo Dynamics 84 BY100 AF F6 3-1/2” 1.00 X 80°W — AF72WS 100 B3001 S-7 / B-0 4 BY125 AF F6 3-3/8” 1.25 X 80°A — AF72WN 100 B3001 S-7 / B-0 4 BY75 AF F3 3-1/2” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Thermo Dynamics (cont’d) LM/LMD100 AFII 150 AF2-9 #0 0.85 X 70°B — HLX70HC 140 B7210 4 3-3/4” LM/LMD110 AFII 150 AF2-9 #3 0.90 X 70°B — HLX70HC 140 B7210 5 3-3/4” LM/LMD75 AFII 150 AF2-9 #0 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Thermo Products (cont'd) OL11-105 AF F3 2-3/4” 0.90 X 80°A — AF76XNOS 100 B3001 S-7 / B-0 — 25 OL11-112 AF F6 2-3/4” 1.00 X 80°A — AF76YBSS 100 B3001 S-7 / B-0 — 27 OL16-125 AF F6 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Thermoflo-Milwaukee (cont’d) HBO-210 AF F12 2-3/4” 1.50 X 80°A — AF104XOSS 100 B3001 S-10 / B-2 9-3/4” 27 HBO-245 AF F16 2-3/4” 1.75 X 70°A — AF104WFSS 100 B3001 S-10 / B-0 9-3/4” 27 LBO 210 AF F12 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes 27 Trane (cont’d) TLF1M087A936-948SAA AF F3 2-3/4” 1.00 X 80°A — AF57XNSS 130 B3001 — — TLF1M087A936-948SAA AF F3 2-3/4” 0.60 X 80°A — AF57XNSS 130 B3001 — — 27 TLF1M087A9V3-9V5SAA AF F3 2-3/4” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Trianco, Inc. / Laars, Inc. (cont’d) HC100 AFG F3 3-5/8” 0.75 X 70°A — AF54WA 140 B2007 S-10 / B-0 3-3/4” HC125 AFG F3 3-5/8” 0.90 X 80°B — AF54WA 140 B2007 S-10 / B-0 3-3/4” HC145 AFG F6 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Trianco, Inc. / Laars, Inc. (cont’d) MAX 100 AFII 150 AFII-9 #4 0.85 X 60°AS — HLX50HE 140 B7203 4 3-1/2” MAX 120 AFII 150 AFII-9 #6 1.00 X 60°AS — HLX50HE 140 B7203 4 3-3/4” MAX 75 AFII 150 AFII-9 #1 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth — Notes Ultimate Eng. (cont’d) K5T 0.75-1.00 AF F3 2-3/4” 0.75-1.00 X 80°A — AF44XN 100 B3001 — K5T 1.00-1.20 AF F6 2-3/4” 1.00-1.20 X 80°A — AF44YB 100 B3001 — — K5T 1.20-1.50 AF F12 2-3/4” 1.20-1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Additional Information Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth 4-1/2” Notes Ultimate Eng. (cont’d) PFO-3T FDVS 0.85 AFG F3 2-3/4” 0.60 X 80°A — AF65XN 140 B2007 — PFO-3T FDVS 1.10 AFG F3 2-3/4” 0.90 X 80°B — AF65XN 140 B2007 — 4-1/2” PFO-4 FDVS 0.65 AFG F0 2-3/4” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Additional Information Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Utica Boiler ACE/OU300,400 AF F4 2-3/4” 1.00 X 80°H — AF53WH 100 B3001 S-6 / B-0 2” ACE/OU500 AF F12 2-3/4” 1.65 X 80°H — AF53XO 100 B3001 S-9 / B-0 2” ACE/OU600 AF F22 3-3/8” 2.
Basic Burner Setup Information Appliance Model Burner Type Head Type Additional Information Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes 3, 9 Utica Boiler (cont’d) TRB6130 AFG V1-0 2-3/4” 1.10 X 60°AS — AFG70MKAQN 140 B2007 S-5 / B-4 2-5/8” TRB6145 AFG V1-2 2-3/4”M 1.10 X 60°AS — AFG70MKAQN 175 B2007 S-5 / B-3 2-5/8” 9 TRB7165 AFG V1-2 2-3/4”M 1.
Basic Burner Setup Information Appliance Model Burner Type Additional Information Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Vaillant (cont'd) F70-45 AFII 150 AF2-6 #0 0.75 X 70°B — HLX 70HD 140 B7210 — — F70-50 AFII 150 AF2-6 #3 0.85 X 60°B — HLX 70HB 140 B7210 — — F70-55 AFII 150 AF2-6 #5 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Additional Information Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Victa-Hytemp 105 OLBF AF F3 3-3/8” 0.75 X 80°B — AF65YHHS 140 B3001 S-5 / B-0 4” 2 150 OLBF AF F6 2-3/4” 1.00 X 80°B — AF65YBHS 140 B3001 S-5 / B-0 4” 2 (2) “HS” on air tube combination = ceramic heat shield on combustion head.
Basic Burner Setup Information Appliance Model Burner Type Additional Information Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth — Notes Weil-McLain B-366-E AF F3 2-3/4” 1.00 X 60°A — AF44XN 100 B3001 — B-466-E AF F3 2-3/4” 1.25 X 80°B — AF44XN 100 B3001 — — B-566-E AF F12 2-3/4” 1.50 X 80°A — AF44XO 100 B3001 — — B-666-E AF F12 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Additional Information Nozzle Type Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes 9 Weil-McLain (cont’d) UO-5 AFG V1-0 2-3/4” 1.10 X 60°B — AFG70MDASN 160 B2007 S-9 / B-1 1-3/4” CHB/CLB 105 NX 9-slot — 0.75 X 60°W — NX70LBHS 140 B8001 3 5-1/4” 2 CHB/CLB 105 NX 9-slot — 0.65 X 60°W — NX70LBHS 140 B8001 2.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Additional Information Nozzle Type Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Williamson Co. (cont’d) R-164-10A AF F4 2-3/4” 0.85 X 80°A — AF72WH 100 B3001 — — R-164-10A AF F4 2-3/4” 0.75 X 80°A — AF72WH 100 B3001 — — R-164-10A AF F4 2-3/4” 0.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Additional Information Nozzle Type Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Williamson Co. (cont’d) 100 CHB/CLB-140-S2 AFG F6 2-3/4” 1.00 X 70°B — AF90YBHSSS 100 B2008 — 7-3/4” 2, 27 CHB/CLB-210 AFG F12 2-3/4” 1.50 X 80°A — AF104XOSS 100 B2007 — — 27 CHB/CLB-245 AFG F16 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Additional Information Nozzle Type Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Williamson Co. (cont’d) WLBO-10A AFG F3 3-3/8” 0.85 X 80°B — AF65YHHSSS 100 B2008 — — 2, 27 WLBO-10A AFG F3 3-3/8” 0.75 X 80°B — AF65YHHSSS 100 B2008 — — 2, 27 WLBO-12A AFG F6 2-3/4” 1.
Basic Burner Setup Information Appliance Model Burner Type Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Additional Information Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes Wise, Inc. (cont’d) OL-150 AF F12 2-3/4” 1.50 X 70°S — AF72XO 100 B3001 S-7 / B-0 — OL-75 AF F3 2-3/4” 0.75 X 80°S — AF72XN 100 B3001 S-7 / B-0 — OL-90 AF F3 2-3/4” 0.
Basic Burner Setup Information Appliance Model Burner Type Additional Information Head Type Static Plate/ Stop Screw Nozzle Type Low Fire Rate Baffle Std. Air Tube Pump Pressure Recom. Chassis Approximate Air Settings* Insertion Depth Notes F12 2-3/4” 1.50 X 70°S — AF67XOFS 100 B2008 S-7 / B-0 — 1 York (cont’d P-FMD20F17001A AFG (1) “FS” on air tube combination = fiber heat shield on combustion head. Yukon 85 M PLUS AFG L1 3-3/8” 0.
Nozzle Capacities Manufacturers / Spray Patterns Nozzle Capacities / U.S. Gallons per hour No. 2 Fuel Oil Operating Pressure: Pounds per Square Inch Rate gph @ 100 psi 125 140 150 175 200 250 275 300 .40 .50 .60 .65 .45 .56 .67 .73 .47 .59 .71 .77 .49 .61 .74 .80 .53 .66 .79 .86 .56 .71 .85 .92 .63 .79 .95 1.03 .66 .83 1.00 1.08 .69 .87 1.04 1.13 .75 .85 90 1.00 1.10 1.20 .84 .95 1.01 1.12 1.23 1.34 .89 1.01 1.07 1.18 1.30 1.42 .92 1.04 1.10 1.23 1.35 1.47 .99 1.13 1.19 1.32 1.46 1.
Helpful Conversion Factors for Heating Systems MultIply by to obtain: Atmosphere (atm) 14.70 Ib. per sq. in. (psi) Boiler Horsepower 34.50 pounds steam/hr @ 212°F. Boiler Horsepower 33,475 BTU per hour Cubic feet (cu. ft.) 7.481 gallons (gal.) Degrees–Centigrade (°C) (°Cx1.8) + 32 degrees–Fahrenheit (°F) Degrees–Fahrenheit (°F) (°F -32) x 5/9 degrees–Centigrade (°C) Gallon, # 2 Oil 7.1 pounds (Ibs.) approx. Gallon, Water B.337 pounds (Ibs.) Horsepower .3 GPH Horsepower–U.S.
Helpful Conversion Factors for Heating Systems Boiler Tube Sizing (Pg. 7– 205 Hoffman data book) Sq.ft. heating surface x 1.15 = Hp x .3 = Gph 10 Water Capacity Per Foot of Pipe Pipe Size 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 5” 6” Gallons Per Foot .023 .040 .063 .102 .17 .275 .39 .53 .69 1.1 1.5 .016 Most Common pipe sizes Sq. Ft. of surface (ext) per 1 foot pipe 3” pipe 3-1/2” pipe 4” pipe 0.916 1.047 1.178 Oll Pressure vs. Nozzle Flow Rate ConversIon 1.
Enhance Performance To help your hydronic customers realize up to 20% energy savings on their heating bills and reduce burner cycling, suggest a Beckett AquaSmart when replacing a Boiler Temperature Control. The Beckett AquaSmart is an advanced Boiler Temperature Control designed for use on residential and light commercial boiler systems. The AquaSmart comes equipped with the Department of Energy (DOE) 2012 compliant HeatManager.