Specifications

Genera| information
General Specification
Table 1 - Burner Specifications
Capacity 'HLX' Heads
Firing rate: - 0.40 - 1.50 GPH
Input: Min./Max - 56,000/210,000 Btu/h
'FBX' Heads
Firing rate: - 0.40 - 1.35 GPH
Input: Min./Max. - 56,000/189,000 Btu/h
Certification/ UL certified to comply with ANSI/UL296 &
Approvals tested to CSA B140.0
Fuels U. S No. 1 or No. 2 heating oil only (ASTM
D396)
Canada No. 1 stove oil or No. 2 furnace oil
only
Electrical Power supply - 120 volts AC, 60 Hz, single
phase
Operating load - 5.8 Amps max
Motor - 1/7 hp, 3450 rpm, NEMA 48M
frame PSC rotation CCW when
facing shaft end
Ignition - Continuous duty solid-state igniter
Fuel pump Outlet pressure - Note 1
Air tube ATC code - See Table 2
Dimensions Height (maximum) - 13 inches
(with cover) Width (maximum) - 14 inches
Depth - 6-11/16 inches
Air tube diameter 3-1/2 inches
Notice Special Requirements
For recommended installation practice in Canada,
refer to the latest version of CSA Standard B139 &
B140.
Concealed damage -- If you discover damage to
the burner or controls during unpacking, notify the
carrier at once and file the appropriate claim.
When contacting Beckett for service information --
Please record the burner serial number (and have
available when calling or writing). You will find the
serial number on the silver label located on the left
rear of the burner. Refer to Figure 1.
inspect/Prepare installation Site
, Clearances to Burner and Appliance
Provide space around burner and appliance for
ease of service and maintenance. Check the mini-
mum clearances against those shown by the ap-
pliance manufacturer and by applicable building
codes.
*Note 1. See appliance manufacturer's burner specifications for
recommended outlet pressure.
Table 2 - Air Tube Combinations (ATC) & Dimensions
ATC codes for usable air tube lengths dim. "A" (Figure 3) Firing rate range (gph)Min-Max
3" 5" 7" 9" ATC Code Head AFII 85 AFII 100 AFII 150
-u HLX30 HLX50 HLX70 HLX90 HB AF2-6 0.4-0.85 gph 0.65-1.00 gph 0.75-1.35 gph
_e o_e _- HLX30 HLX50 HLX70 HLX90 HC AF2-9 N/A 0.65-1.00 gph 0.75-1.50 gph
_ OI ob
"d
HLX30 HLX50 HLX70 HLX90 HD AF2-6 0.40-0.85 gph 0.65-1.00 gph 0.75-1.10 gph
o HLX30 HLX50 HLX70 HLX90 HE AF2-9 N/A 0.65-1.00 gph 0.75-1.35 gph
_- FBX30 FBX50 FBX70 FBX90 HFXS FB0 0.40-0.65 gph 0.55-0.75 gph 0.75-1.00 gph
-o FBX30 FBX50 FBX70 FBX90 HGXS FB3 0.55-0.85 gph 0.55-1.10 gph 0.85-1.20 gph
-u _ FBX30 FBX50 FBX70 FBX90 HHXS FB4 N/A 0.75-1.10 gph 1.10-1.25 gph
® FBX30 FBX50 FBX70 FBX90 HIXS FB6 N/A 0.85-1.15 gph 1.15-1.35 gph
I
HB 6 slot
'!
1
HC 9 slot
3-5/32" I I
I,D,
]_
2-15/16"
I.D.
1
HD 6 slot
HE 9 slot
RWB 6104 BAFII R01 Page 5