Operating instructions

7
Setting the Final Positions
There are 4 ways to set the nal positions:
a) Lower position to upper position without buffer
b) Lower position to upper buffer
c) Anti-lifting device at the lower nal position to upper buffer
d) Anti-lifting device at the lower nal position to upper position without buffer (only via installation set)
The nal limit position becomes xed, after the tubular drive has turned off automatically, in the desired position, three times.
Note
If, due to an obstruction, the tubular drive switches off prematurely while travelling upwards and down-
wards, it is possible to relieve the obstacle and to remove it by briey travelling in the opposite direction,
and to set the desired nal position by travelling upwards/downwards again.
Attention
The installation assembly set is not suitable for continuous op-
eration and has only been designed for start-up.
Connect the wires of the tubular drive to the same coloured wires of the installa-
tion assembly set (Art. No. 4901 002 181 0) or the operating element and switch
on the mains supply.
a) Lower position to upper position without buffer
Note
There is no shutter length adjustment for this nal position set-
ting.
Setting the nal positions via the switches
Push both switches to the delete position.
Actuate a brief start command.
Travel to the desired lower nal position.
Move the DOWN direction switch from the delete position to the programmed
position.
Subsequently travel to the desired upper nal position.
Now move the UP direction switch from the delete position to the programmed
position.
The nal positions have now been set.
Programming position
Switch
Delete position
Directional arrows