Operating instructions

14
Assembly and Operating Instructions
12b)
Note
This function is only available with the transmitters MemoControl MC441 and MC411 from Becker Centronic
control programs.
Every tubular drive can store switching times for one UP and one DOWN command.
If the sliding switch is set to “Clock” this roller shutter command is repeated every 24 hours.
The position of the manual/auto sliding switch is unimportant when programming the switching time. All previously stored switch-
ing times are deleted accordingly.
1. Adjust the roller shutters, if necessary, until they are in the limit position opposite to the desired running direction.
2. Wait until the time at which the automatic control command is to be executed.
3. At the preset time activate the desired direction key and hold down until the roller shutter system stops briey after approxi-
mately 6 seconds and then moves unto the limit position.
4. Release direction key.
The tubular drive will automatically store the current time for this control command.
12b) Activating the tubular drive programme mode with the radio switch
The tubular drive goes into programme
mode for 3 minutes.
Now press the learn button of the new
master transmitter for 10 seconds.
The tubular drive makes a “clack-clack”
sound to conrm.
The new master transmitter has been
programmed and the old master trans-
mitter has been deleted.
Slide the radio switch into the inner po-
sition. If the radio switch is already in
this position, slide the switch outwards
and then back to the inner position
again.
Action Response
Programming the switching times
Deleting the switching times
Note
Both switching times are always deleted in this process.
In order to delete the times the UP and DOWN control commands are to be triggered, press the STOP button for 10 seconds. This
is acknowledged by a double click of the tubular drive.
The switching times have been deleted.
Clack
Clack
Disposal
Declaration of Conformity
This product consists of various materials which must be disposed of correctly. Please nd out more about relevant national
legislations governing the recycling and disposal systems for this product.
The packaging material must be disposed of correctly.
Becker tubular drives display the CE mark. These drives comply with valid EU directives and meet EMC requirements.