Operating instructions
Technical data dia. 45
Type R12/17
HK
R15/17
HK
R20/17
HK
R25/17
HK
Rated torque (Nm) 12 15 20 25
Output speed (rpm)
17 17 17 17
Limit switch range 38 revolutions
Supply voltage 230 V AC / 50 Hz
Connected load (W) 110 140 160 175
Rated current consumption (A) 0.50 0.65 0.75 0.80
Mode S2 4 min
Degree of protection IP 44
Min. tube inside diameter (mm) 47
Type R30/17
HK
R40/17
HK
R50/11
HK
Rated torque (Nm) 30 40 50
Output speed (rpm)
17 17 11
Limit switch range 38 revolutions
Supply voltage 230 V AC / 50 Hz
Connected load (W) 205 260 240
Rated current consumption (A) 0.90 1.15 1.10
Mode S2 4 min
Degree of protection IP 44
Min. tube inside diameter (mm) 47
Technical data dia. 58
Type L44/14
HK
L50/11
HK*
L50/17
HK
L60/11
HK
L60/17
HK*
Rated torque (Nm) 44 50 50 60 60
Output speed (rpm)
14 11 17 11 17
Limit switch range 38 revolutions
Supply voltage 230 V AC / 50 Hz
Connected load (W) 255 235 315 265 380
Rated current consumption (A) 1.20 1.05 1.40 1.20 1.75
Mode S2 4 min
Degree of protection IP 44
Min. tube inside diameter (mm) 60
11