Installation manual
57
Controls
for sun protection
3. Setting the sun threshold
Use the tool provided to turn the sun
threshold regulator to the desired
setting.
The sun threshold has 15 possible set-
tings (approx. 2 klux to 100 klux). When
slowly turning the regulator, the tubu-
lar drive clicks to indicate the setting
changes.
4. Setting the wind threshold
Use the tool provided to turn the wind
threshold regulator to the desired
setting.
The wind threshold has 11 possible set-
tings (approx. 2 m/s to 22 m/s). When
slowly turning the regulator, the tubu-
lar drive clicks to indicate the setting
changes.
5. Checking settings
After the threshold values are set, the
system switches to the TEST mode
automatically. In the TEST mode, the
shade function and wind monitoring
times are shortened. The functions can
be controlled in automatic mode.
End the test mode by using the slide switch
on the SWC441 to move from automatic
mode to manual mode and back to auto-
matic mode. If the slide switch is not op-
erated within 15 minutes, the test mode is
ended automatically.
Manual mode Automatic mode