Installation manual
45
Drives
for sun protection
Programming the limit positions via the programming
unit of type PS(+)
1. Programming the extend-
ing limit position with the
programming unit
Connect the wires in the connecting
cables of the drive to the wires of the
same colour in the Becker program-
ming unit.
At least one switch on the drive head
must be in position
.
Travel the curtain to the desired
position and press the programming
button until the drive clicks once.
2. Programming the retract-
ing limit position with the
programming unit
Retracting limit position stop
Travel the curtain towards the
stop until the drive stops auto-
matically.
Retracting limit position point
Travel the curtain to the de-
sired upper position and press
the programming button on the
programming unit until the drive
clicks once.
3. Deleting the limit positions
using the programming unit
Press the programming button
and keep it pressed.
Press the
button and keep it
pressed.
Release the programming button
.
Press the programming button
again, until the drive clicks twice.
If the drive is situated between the
limit positions, both limit positions
are deleted. If the drive is situated
in one of the limit positions, only this
position will be deleted.
1 x click
1 x click