PS(+) drives 
Type plate for PS(+) drives 
  Type designation: e.g., R 30/17 C PS+
R  size of drive 
(tube diameter) 
P – 35 mm 
R – 45 mm 
L – 58 mm
30/17  rated torque/output speed
C  pluggable connecting cable
P  point to point programming 
possible
S  electronic limit switching 
for sun protection
+  higher closing force 
for cassette awnings
Operating mode (short-period 
operation S2)
  After  4 minutes  of  continuous operation, 
the drive must be allowed to cool off.
  Serial number: e.g., 09 01 961657
09  year 2009
01  calendar week
961657 consecutive number
Connecting PS(+) drives 
Several  drives  with  electronic  limit  switch-
ing  can  be  connected  in  parallel to  a  control  
section. The  maximum  number  of synchro-
nously controlled drives depends on the load 
capacity of the operator control.
The changeover time for switching the running 
direction  must  be at  least  0.5 seconds.  The 
switch and controls must not execute simulta-
neous RETRACT and EXTEND commands.
The following applies to operator controls with 
a 5A contact load rating:
R5/20 PS - R12/17 C PS(+) = 
max. 5 drives
R20/17 C PS(+) - R60/17 C PS(+) = 
max. 3 drives
R70/17 C PS(+) - R120/11 C PS(+) = 
max. 2 drives
Mains
Drive
Drive 2Drive 1