4
Which type of roller shutter drive has been installed?
How to identify the type of drive:
General
If the drive produces a loud noise and the tube does
not turn, the drive is a type M. Replace the program-
ming unit immediately with one that is suitable for an
M drive.
If the drive clicks twice, a type R(+) has been installed.
If the drive clicks once or does not react, it is a PicoR+,
PP(+), PR+, RF(+) or PRF+ drive.
Let the drive turn twice and then press the program-
ming button again for 2 seconds (another click
indicates that a second limit position has been set). Let
the drive turn once in the opposite direction and carry
out the following procedure for deleting:
Possible drive types:
Type M: Drive with mechanical limit switching
Type R(+): Drive with electronic limit switching and sensitive obstruction
detection (1997-2009)
Type Pico R+: Drive with electronic limit switching for the mini tube (1999-2007)
Type RF(+): Drives with radio receiver (40 MHz) and sensitive obstruction
detection (2000-2002)
Type PRF+: Drives with radio receiver (868.3 MHz) and point to point program-
ming (from 2003 onwards)
Type PR+: Drive with electronic limit switching and point to point programming
(from 2005 onwards)
Type RP(+): Drive with electronic limit switching, point to point programming and
sensitive obstruction detection (from 2009 onwards)
+ means: suitable for rigid tube connectors or anti-lifting devices
Even if the drive is already installed, the type can
be identified via the programming unit. To this end,
connect the wires in the connecting cables of the drive
to those of the same colour in the Becker programming
unit. Perform the following steps one after the other.
Press the programming button
for 2 seconds.