Installation manual
34
Type plate for the M drive
Connecting M drives
Drives with mechanical limit switching must
not be connected in parallel to a control
section. A discharge of the capacitor could
damage the limit switch. This would cause the
limit positions to be “overrun”.
The changeover time for switching the running
direction must be at least 0.5 seconds. The
switch and controls must not execute simulta-
neous RETRACT and EXTEND commands.
Mains
Drive
Drive 2Drive 1
M drives
Type designation: e.g., R 8/17 C M
R size of drive
(tube diameter)
P – 35 mm
R – 45 mm
L – 58 mm
8/17 rated torque/output speed
C pluggable connecting cable
M mechanical limit switch
Operating mode (short-period
operation S2)
After 4 minutes of continuous operation,
the drive must be allowed to cool off.
Serial number: e.g., 08 40 961630
08 year 2008
40 calendar week
961630 consecutive number
Mains