Installation manual
28
Setting the limit positions for type PRF +
3. Deleting the limit positions
using the master transmitter
Press the programming button and the
STOP button simultaneously until the
drive clicks twice after 10 seconds.
If the roller shutters are situated
between the limit positions, both limit
positions are deleted in the procedure. If
the roller shutters are situated in one of
the limit positions, only this position will
be deleted.
1. Programming the upper limit
position with the master
transmitter
To upper stop
Travel the roller shutters towards the
upper stop until the drive stops auto-
matically.
To upper point
Travel the roller shutters to the de-
sired upper position. Then press the
programming button and the UP but-
ton until the drive clicks once.
2. Programming the lower limit
position with the master
transmitter
To lower point
Travel the roller shutters to the
desired position. Then press the
programming button and the DOWN
button until the drive clicks once.
To lower stop (only with anti-lift-
ing devices)
Travel the roller shutters downwards
until the drive switches off automati-
cally.
PRF+ drives
1 x click
2 x click