26
Type plate for PRF+ drives
Type designation: e.g., R8/17 C PRF+
R size of drive
(tube diameter)
P – 35 mm
R – 45 mm
8/17 rated torque/output speed
C pluggable connecting cable
P point to point programming pos-
sible
R electronic limit switches
for roller shutters
F radio receiver
+ suitable for
anti-lifting device
Operating mode (short-period
operation S2)
After 4 minutes of continuous operation,
the drive must be allowed to cool off.
Serial number: e.g., 08 49 20071
08 year 2008
49 calendar week
20071 consecutive number
Connecting PRF+ drives
Drives with electronic limit switching and inte-
grated radio receiver are connected directly
to the power supply. The brown wire and the
black wire are clasped together on the outer
conductor L1.
Mains
Drive
PRF+ drives