Installation manual
25
Drives
for roller shutters
Programming the limit positions with the
programming unit of type PR+
1. Setting the lower limit position
with the programming unit
Connect the wires in the connecting
cables of the drive with the wires of the
same colour in the Becker programming
unit. Set both switches to programming
setting ( ).
To lower point
Travel the roller shutters to the de-
sired position and press the program-
ming button on the programming unit
until the drive clicks once.
To lower stop
When using anti-lifting devices (fixed
mounting), travel the roller shut-
ters downwards until the drive stops
automatically.
2. Setting the upper limit posi-
tion with the programming unit
To upper stop
Travel the roller shutters towards the
upper stop until the stops automati-
cally.
To upper point
Travel the roller shutters to the
desired upper position and press the
programming button on the program-
ming unit until the drive clicks once.
3. Deleting the limit positions
using the programming unit
Press the programming button and
keep it pressed.
Press the button and keep it
pressed.
Release the programming button .
Press the programming button again,
until the drive clicks twice.
If the drive is situated between the limit
positions, both limit positions are delet-
ed. If the drive is situated in one of the
limit positions, only this position will be
deleted.
1 x click
1 x click