Installation manual
22
PR+ drives
Type plate for PR+ drives
Type designation: e.g., R 8/17 C PR+
R size of drive
(tube diameter)
P – 35 mm
R – 45 mm
12/17 rated torque/output speed
C pluggable connecting cable
P point to point programming
possible
R electronic limit switching
for roller shutters
+ suitable for
anti-lifting device
Operating mode (short-time
operation S2)
After 4 minutes of continuous operation,
the drive must be allowed to cool off.
Serial number: e.g., 08 40 961630
08 year 2008
40 calendar week
961630 consecutive number
Connecting PR+ drives
Several drives with electronic limit switch-
ing can be connected in parallel to a control
section. The maximum number of synchro-
nously controlled drives depends on the
respective current consumption but must not
exceed 5.
The changeover time for switching the run-
ning direction must be at least 0.5 seconds.
The switch and controls must not execute
simultaneous UP and DOWN commands.
Mains
Drive
Drive 2Drive 1
Mains