Installation manual
21
Drives
for roller shutters
3. Deleting the limit positions 
via the programming unit
Press  the  programming  button    and 
keep it pressed.
Press  the 
  button    and  keep  it 
pressed.
Release the programming button 
.
Press  the  programming  button 
  again 
until the drive clicks twice.
Note:  When  the  shutters  close  for 
the first  time (installation  run), the 
drive  uses  less  force  for  safety 
reasons.    If  the  force  is  configu-
rated  close  to  the  limit,  the  drive 
may  stop  before  reaching  the  up-
per  limit  position.  After  revers-
ing  a  short  way,  the  drive  is  started  
again until it reaches the upper limit 
position.
The  drive  indicates  the  lack  of  a  limit 
position  by  driving  forward,  stopping 
and then continuing (limit position status 
indicator). Once the limit positions have 
been  detected  3  times  consecutively 
without  problems  (3  opening  and  clos-
ing movements), the drive saves the limit 
positions. 
4. Activating the cyclic curtain 
length adjustment (optional)
By  pressing  the  programming  button 
on the programming unit for 3 seconds, 
you  activate the  cyclical curtain  length 
adjustment.  The  drive  confirms  the
action by clicking three times.
After  the  programming  is  completed  (3 
complete  opening  and  closing  move-
ments),  the  roller  shutters  stop  shortly 
before reaching the upper  limit position 
and  will  only  reach  the  stop  every  32
nd 
time (correction run). 
3 x click