Installation manual
15
Drives 
for roller shutters
Information on the R(+) drive
R(+) drives with electronic limit switching 
detect and program both limit  positions 
automatically. 
In order for the drive to detect the upper 
limit  position  without  problems,  a  de-
fined stop must be present (angled strip 
or mechanical stop).
Installation with anti-lifting 
devices of type R+
The  anti-lifting  device  must  be  secure-
ly engaged and  be pressing the roller  
shutters onto the window sill. 
The limit positions can be set using any 
operator control. 
Limit  positions  are  deleted  using  the  
programming unit.
Connect  the  wires  in  the  connecting  
cable of the drive to the wires of the same 
colour in the programming unit.
Installation with springs of type R
No  more  than  one  roller  shutter  bar 
should  jut  out  over  the  intake  guide.  In 
the lower limit position, the springs must 
counteract the tube’s rotary motion. The 
springs should be mounted 30 cm apart 
from one another.










