Drives
for roller shutters
Information on the R(+) drive
R(+) drives with electronic limit switching
detect and program both limit positions
automatically.
In order for the drive to detect the upper
limit position without problems, a de-
fined stop must be present (angled strip
or mechanical stop).
Installation with anti-lifting
devices of type R+
The anti-lifting device must be secure-
ly engaged and be pressing the roller
shutters onto the window sill.
The limit positions can be set using any
operator control.
Limit positions are deleted using the
programming unit.
Connect the wires in the connecting
cable of the drive to the wires of the same
colour in the programming unit.
Installation with springs of type R
No more than one roller shutter bar
should jut out over the intake guide. In
the lower limit position, the springs must
counteract the tube’s rotary motion. The
springs should be mounted 30 cm apart
from one another.