Installation manual

14
R(+) drives
Type plate for R(+) drives
Type designation: e.g., R 8/17 R+
R size of drive
(tube diameter)
P – 45 mm
8/17 rated torque/output speed
R electronic limit switching
for roller shutters
+ suitable for
anti-lifting device
Operating mode (short-period
operation S2)
After 4 minutes of continuous operation,
the drive must be allowed to cool off.
Serial number: e.g., 05 48 50542
05 year 2005
48 calendar week
50542 consecutive number
Connecting R(+) drives
Several drives with electronic limit switch-
ing may be connected in parallel to a control
section. The maximum number of synchro-
nously controlled drives depends on the
respective current consumption but must not
exceed 5.
The changeover time for switching the running
direction must be at least 0.5 seconds. The
switch and controls must not execute simulta-
neous UP and DOWN commands.
Mains
Drive
Drive 2Drive 1
Mains