Installation manual
Preface Using the installation manual The installation manual describes the commissioning of Becker tubular drives for roller shutters and sun protection as well as the commissioning of specific Becker controls. This manual is intended for technicians who have been trained by Becker-Antriebe GmbH. It is essential that you follow the safety instructions for the installation and commissioning of tubular drives and controls on pages 60-61. Disregarding them can result in serious injuries.
SC431 control unit Page 30 How to identify the type of drive M drives S(+) drives PS(+) drives SE-B(+) drives PSF(+) drives Page 32 Page 34 Page 38 Page 42 Page 46 Page 50 SWS241 control set SWS441/SWS641 control set SC211 control Page 54 Page 56 Page 58 Drives for roller shutters Page 4 Page 6 Page 10 Page 14 Page 18 Page 22 Page 26 3 Controls for sun protection Drives for sun protection Controls for roller shutters Roller shutters How to identify the type of drive M drives PicoR+ drives R(+)
General Which type of roller shutter drive has been installed? Possible drive types: Type M: Type R(+): Drive with mechanical limit switching Drive with electronic limit switching and sensitive obstruction detection (1997-2009) Type Pico R+: Drive with electronic limit switching for the mini tube (1999-2007) Type RF(+): Drives with radio receiver (40 MHz) and sensitive obstruction detection (2000-2002) Type PRF+: Drives with radio receiver (868.
Press the button and keep it pressed. and keep it pressed. Release the programming button Press the programming button clicks twice. . again, until the drive If the drive does not react, RF(+) drives with integrated radio receiver (up to 2002) or PRF+ drives (from 2003 onwards) have been installed. If the drive clicks twice, PicoR+, RP(+) or PR+ drives were installed. Press the programming button again. If the drive does not react, a PicoR+ drive (up to 2007) has been installed.
M drives Type plate for the M drive Type designation: e.g., R 8/17 C M R size of drive (tube diameter) P – 35 mm R – 45 mm L – 58 mm 8/17 rated torque/output speed C pluggable connecting cable M mechanical limit switch Operating mode (short-period operation S2) After 4 minutes of continuous operation, the drive must be allowed to cool off. Serial number: e.g.
Before installation, make sure that the drive adapter safety catch has engaged (is screwed on tightly). Mark the position of the drive adapter on the tube and drill a 4 mm hole at this point. Secure the drive adapter against axial displacement in the tube using a screw or a rivet. The arrow on the drive head indicates the direction of rotation at . The limit position is set using the corresponding adjuster, for example, the flexible tool (item no. 4933 200 002 0).
M drives Setting the limit positions for M drives 1. Setting the lower limit position After the tube is installed, move the drive downwards until it switches off automatically. Using the flexible tool, turn the corresponding adjuster in the + direction (clockwise) until the tube is in a suitable position for connecting the roller shutter to the tube. Switch off the down direction and connect the roller shutters to the tube (mount the springs).
Travel the roller shutters upwards until the drive switches off automatically via the limit switch for the upper limit position. Note: When delivered (from the factory), the limit switch range is preset to 2 revolutions in the up and down directions. While moving up, the drive switches off after 4-5 revolutions. Turn the corresponding adjuster in the + direction (clockwise) until the roller shutters are in the upper limit position. 9 Drives for roller shutters 2.
PicoR+ drives Type plate for PicoR+ drives Type designation: e.g., P 9/16 R+ P size of drive (tube diameter) P – 35 mm 9/16 rated torque/output speed R electronic limit switching for roller shutters + suitable for anti-lifting device Operating mode (short-period operation S2) After 4 minutes of continuous operation, the drive must be allowed to cool off. Serial number: e.g.
PicoR+ drives with electronic limit switching detect and program the upper limit position automatically. In order for the drive to detect the upper limit position without problems, a defined stop must be present (angled strip or mechanical stop). The springs are attached to the mini tube using tube clamps. This stops the springs from dragging against the drive. The limit positions can be set using any operator control. Limit positions are deleted using the programming unit.
PicoR+ drives Programming the end positions for type PicoR+ 1. Programming the upper limit position First, travel the roller shutters towards the upper limit position until the drive switches off automatically. Note: When the shutters move upwards for the first time (installation run) the drive uses less force for safety reasons. If the force is configurated close to the limit, the drive may stop before reaching the upper limit position.
Travel the roller shutters towards the upper limit position again, without interruption, until the drive switches off automatically. This time, the drive learns the distance between the limit positions and automatically concludes the programming phase. 4. Deleting the limit positions using the programming unit Press the programming button keep it pressed. Press the pressed. button and and keep it Release the programming button Press the programming button until the drive clicks twice.
R(+) drives Type plate for R(+) drives Type designation: e.g., R 8/17 R+ R size of drive (tube diameter) P – 45 mm 8/17 rated torque/output speed R electronic limit switching for roller shutters + suitable for anti-lifting device Operating mode (short-period operation S2) After 4 minutes of continuous operation, the drive must be allowed to cool off. Serial number: e.g.
R(+) drives with electronic limit switching detect and program both limit positions automatically. In order for the drive to detect the upper limit position without problems, a defined stop must be present (angled strip or mechanical stop). Installation with springs of type R No more than one roller shutter bar should jut out over the intake guide. In the lower limit position, the springs must counteract the tube’s rotary motion. The springs should be mounted 30 cm apart from one another.
R(+) drives Programming the limit position when installing with springs of type R 1. Programming the upper limit position First, travel the roller shutters towards the upper limit position until the drive switches off automatically. Note: When the shutters close for the first time (installation run), the drive uses less force for safety reasons. If the force is configurated close to the limit, the drive may stop before reaching the upper limit position.
Programming the limit position when installing with anti-lifting devices of type R+ Drives for roller shutters 1. Programming the upper limit position First, travel the roller shutters towards the upper limit position until the drive switches off automatically. Note: When the shutters close for the first time (installation run), the drive uses less force for safety reasons. If the force is configurated close to the limit, the drive may stop before reaching the upper limit position.
RP(+) drives Type plate for RP(+) drives Type designation: e.g., R 8/17RP+ R size of drive (tube diameter) P – 45 mm 8/17 rated torque/output speed P point to point programming possible R electronic limit switching for roller shutters + suitable for anti-lifting device Operating mode (short-period operation S2) After 4 minutes of continuous operation, the drive must be allowed to cool off. Serial number: e.g.
RP(+) drives with electronic limit switching detect and program both limit positions automatically. If no stops exist, limit switch points are programmed. In order for the drive to detect the upper limit position automatically, a defined stop must be present (angled strip or mechanical stop). Installation with springs of type RP No more than one roller shutter bar should jut out over the intake guide. In the lower limit position, the springs must counteract the tube’s rotary motion.
RP(+) drives Programming the limit positions with the programming unit of type RP(+) 1 x click 1. Programming the upper limit position Connect the wires in the connecting cables of the drive to the wires of the same colour in the Becker programming unit. To upper stop Travel the roller shutters towards the upper limit position until the drive automatically stops.
Press the programming button keep it pressed. Press the pressed. button Drives for roller shutters 3. Deleting the limit positions via the programming unit and and keep it Release the programming button . Press the programming button until the drive clicks twice. again Note: When the shutters close for the first time (installation run), the drive uses less force for safety reasons. If the force is configurated close to the limit, the drive may stop before reaching the upper limit position.
PR+ drives Type plate for PR+ drives Type designation: e.g., R 8/17 C PR+ R size of drive (tube diameter) P – 35 mm R – 45 mm 12/17 rated torque/output speed C pluggable connecting cable P point to point programming possible R electronic limit switching for roller shutters + suitable for anti-lifting device Operating mode (short-time operation S2) After 4 minutes of continuous operation, the drive must be allowed to cool off. Serial number: e.g.
PR+ drives with electronic limit switching detect and program the limit positions automatically if stops exist. If no stops exist, limit switch points are programmed. In order for the drive to detect the upper limit position without problems, a defined stop must be present (angled strip or mechanical stop). Installation with anti-lifting devices The anti-lifting devices must be securely engaged and be pressing the roller shutters onto the window sill.
PR+ drives Setting the limit positions with switches of type PR+ 1. Delete both limit positions with the switches Set both switches to O and give a short driving command. 2. Setting the lower limit position with the switches To lower point Travel the roller shutters to the desired position and switch the corresponding switch from O to . To lower limit Set both switches to . When using anti-lifting devices (fixed mounting), travel the roller shutters downwards until the drive stops automatically. 3.
1. Setting the lower limit position with the programming unit Drives for roller shutters Programming the limit positions with the programming unit of type PR+ 1 x click Connect the wires in the connecting cables of the drive with the wires of the same colour in the Becker programming unit. Set both switches to programming setting ( ). To lower point Travel the roller shutters to the desired position and press the programming button on the programming unit until the drive clicks once.
PRF+ drives Type plate for PRF+ drives Type designation: e.g., R8/17 C PRF+ R size of drive (tube diameter) P – 35 mm R – 45 mm 8/17 rated torque/output speed C pluggable connecting cable P point to point programming possible R electronic limit switches for roller shutters F radio receiver + suitable for anti-lifting device Operating mode (short-period operation S2) After 4 minutes of continuous operation, the drive must be allowed to cool off. Serial number: e.g.
Information on the PRF+ drive Drives for roller shutters PRF+ drives with electronic limit switching detect and program the limit positions automatically if stops exist. If no stops exist, limit switch points are programmed. In order for the drive to detect the upper limit position without problems, a defined stop must be present (angled strip or mechanical stop).
PRF+ drives Setting the limit positions for type PRF + 1. Programming the upper limit position with the master transmitter 1 x click To upper stop Travel the roller shutters towards the upper stop until the drive stops automatically. To upper point Travel the roller shutters to the desired upper position. Then press the programming button and the UP button until the drive clicks once. 2.
4. Programming the intermediate position Drives for roller shutters Setting the intermediate positions for type PRF + 1 x click Move the drive to the required intermediate position and press the STOP and DOWN buttons until the drive clicks once. To drive up to the intermediate position, press the DOWN button twice in one second. 5. Programming the ventilation position Move the drive to the required ventilation position and press the STOP and UP buttons until the drive clicks once.
Control unit SC431 Commissioning the radio-controlled light sensor SC431 Programming the SC431 1. Turn the housing cover (2 mm) clockwise and remove it. 2. Press the programming button on the master transmitter (the transmitter that was programmed first) until the receiver clicks once. 1 x click Master transmitter 3. Press the programming button of the SC431 until the receiver confirms once. 4. Now press the programming button of the SC431 again, until the receiver confirms twice.
1. Set the DIP switches 1 and 4 to ON. This activates the sun protection and the configuration mode (optical tool with indicator lamps). 2. By turning the sun threshold regulator in the configuration mode, you can adjust the the sun threshold setting with help from the indicator lamps. 3. Once the desired threshold value has been set, switch DIP switch 4 back to OFF.
General Which type of sun protection drive has been installed? Possible drive types: Type M: Type S(+): Type SF(+): Drive with mechanical limit switching Drive with electronic limit switching (1997-2003) Drives with electronic obstruction detection and radio receiver (2000-2003) Type PS(+): Drives with electronic limit switching and point to point programming (from 2003 onwards) Type SEB(+): Drives with electronic limit switching and automatic reversal (fabric stretching) in the extending limit position (f
Travel the curtain downwards and press the programming button again for 2 seconds. If the drive does not react or if it clicks once, start retracting the curtain until the drive stops at the limit position stop or at a pre-programmed switch-off point. If the drive clicks twice, press the programming button again until the drive clicks once. Then retract the curtain until the drive stops at the limit position stop or at a pre-programmed switch-off point. Both limit positions are now programmed in the drive.
M drives Type plate for the M drive Type designation: e.g., R 8/17 C M R size of drive (tube diameter) P – 35 mm R – 45 mm L – 58 mm 8/17 rated torque/output speed C pluggable connecting cable M mechanical limit switch Operating mode (short-period operation S2) After 4 minutes of continuous operation, the drive must be allowed to cool off. Serial number: e.g.
Information on the M drive Before installation, make sure that the drive adapter safety catch has engaged (is screwed on). Mark the position of the drive adapter on the tube and drill a 4 mm hole at this point. Secure the drive adapter against axial displacement in the tube using a screw or a rivet. The arrow on the drive head indicates the direction of rotation at . The limit position is set via the corresponding adjuster using the flexible tool (item no. 4933 200 002 0).
M drives Setting the limit positions for M drives 1. Setting the extending limit position After the tube is installed, move the drive in the extending direction until it stops automatically. Using the flexible tool, turn the corresponding adjuster in the + direction (clockwise) until the tube is in a suitable position for connecting the curtain with the tube. Connect the curtain with the tube.
Switch off the retracting mechanism. Using the flexible tool, turn the adjuster for the extending limit position 3-10 revolutions in the - direction (depending on how many times the fabric is wrapped around the tube when the curtain is extended). 2. Setting the retracting limit position Using the flexible tool, turn the adjuster for the extending limit position in the + direction (clockwise), until the desired extending position is reached.
S(+) drives Type plate for S(+) drives Type designation: e.g., R 20/17 S+ R size of drive (tube diameter) R – 45 mm L – 58 mm 20/17 rated torque/output speed S electronic limit switches for sun protection + higher closing force for cassette awnings Operating mode (short-period operation S2) After 4 minutes of continuous operation, the drive must be allowed to cool off. Serial number: e.g.
Information on the S(+) drive S(+) drives with electronic limit switching detect and program the closing limit position automatically if a permanent stop exists. S drives S drives are used to operate screens, awnings and conservatory shading. S+ drives The limit positions can be set via the programming unit. Connect the wires in the connecting cable of the drive to the wires of the same colour in the programming unit.
S(+) drives Programming the limit positions with the programming unit of type S(+) 1 x click 1. Programming the extending limit position via the programming unit Connect the wires in the connecting cables of the drive to the wires of the same colour in the Becker programming unit. Travel the curtain to the desired position and press the programming button until the drive clicks once. 2.
3. Deleting the limit positions using the programming unit 2 x click Drives for sun protection Press the programming button on the programming unit until the drive clicks twice.
PS(+) drives Type plate for PS(+) drives Type designation: e.g., R 30/17 C PS+ R size of drive (tube diameter) P – 35 mm R – 45 mm L – 58 mm 30/17 rated torque/output speed C pluggable connecting cable P point to point programming possible S electronic limit switching for sun protection + higher closing force for cassette awnings Operating mode (short-period operation S2) After 4 minutes of continuous operation, the drive must be allowed to cool off. Serial number: e.g.
Information on the PS(+) drive PS(+) drives with electronic limit switching detect and program the closing limit position automatically if a permanent stop exists. If no stop exists, a limit switch point is programmed. PS drives PS drives are used to operate screens, awnings and conservatory shading. PS+ drives The limit positions can be set using the programming unit or the switch on the drive head.
PS(+) drives Setting the limit positions via the switches of type PS(+) 1. Delete both limit positions with the switches Set both switches to O and execute a short drive command. 2. Programming the extending limit position Travel the curtain to the desired position and switch the corresponding switch from O to . 3. Programming the retracting limit position Retracting limit position stop Travel the curtain towards the stop until the drive stops automatically.
Programming the limit positions via the programming unit of type PS(+) 1 x click 1. Programming the extending limit position with the programming unit Connect the wires in the connecting cables of the drive to the wires of the same colour in the Becker programming unit. At least one switch on the drive head must be in position . Travel the curtain to the desired position and press the programming button until the drive clicks once. 2.
SE-B(+) drives Type plate for SE-B(+) drives Type designation: e.g., R 40/17 SE-B+ R size of drive (tube diameter) R – 45 mm L – 58 mm 40/17 rated torque/output speed S electronic limit switching for sun protection E-B automatic fabric stretching in the extending limit position + higher closing torque for cassette awnings Operating mode (short-period operation S2) After 4 minutes of continuous operation, the drive must be allowed to cool off. Serial number: e.g.
Information on the SE-B(+) drive SE-B(+) drives with electronic limit switching detect and program the closing limit position automatically. A fixed stop must be available for the retracting limit position. An automatic reversal function in the extending limit position ensures that the fabric is stretched. SE-B drives SE-B+ drives SE-B+ drives are used to operate cassette awnings that require a higher closing torque. The cassette is then always closed completely.
SE-B(+) drives Programming the limit positions with the programming unit of type SE-B(+) 1 x click 1. Programming the extending limit position with the programming unit Connect the wires of the tubular drive to those of the same colour in the programming unit. Travel the curtain to the desired position and press the programming button until the drive clicks once. Note: If the drive clicks twice, an extending limit position had already been saved, which has now been deleted.
3. Deleting the limit positions using the programming unit Press the programming button and keep it pressed. Press the pressed. button and keep it Release the programming button . Press the programming button again, until the drive clicks twice. Drives for sun protection If the drive is situated between the limit positions, both limit positions are deleted. If the drive is situated in one of the limit positions, only this position will be deleted.
PSF(+) drives Type plate for PSF(+) drives Type designation: e.g., R30/17C PSF+ R size of drive (tube diameter) P – 35 mm R – 45 mm L – 58 mm 30/17 rated torque/output speed C pluggable connecting cable P point to point programming possible S electronic limit switching for sun protection F radio receiver + higher closing torque for cassette awnings Operating mode (short-period operation S2) After 4 minutes of continuous operation, the drive must be allowed to cool off. Serial number: e.g.
Information on the PSF(+) drive PSF(+) drives with electronic limit switching detect and program the retracting limit position automatically if a permanent stop exists. If no stop exists, a limit switch point is programmed. PSF drives PSF drives are used to operate screens, awnings and conservatory shading. PSF+ drives PSF+ drives are used to operate cassette awnings that require a higher closing torque. The cassette is then always closed completely.
PSF(+) drives Setting the limit positions for type PSF(+) 1. Programming the extending limit position via the programming unit 1 x click Travel the curtain to the extending limit position. Then press the programming button and the extending button until the drive clicks once. 2. Programming the retracting limit position via the master transmitter 1 x click Retracting limit position stop Travel the curtain towards the upper stop until the drive stops automatically.
Setting the intermediate positions for type PSF(+) 4. Programming intermediate position I 1 x click Travel the curtain to the desired intermediate position and press the STOP and EXTEND buttons until the drive clicks once. To travel to intermediate position I, press the EXTEND button twice within one second. 5. Programming intermediate position II 1 x click To travel to intermediate position II, press the RETRACT button twice within one second. 6.
SWS241 control set Commissioning the radio-controlled Sun-Wind-Set with handheld transmitter and SWS241 sensor 1. Programming the master transmitter a. Travel the curtain to a centre position using the UP/STOP/DOWN toggle switch. b. Press the programming button on the SWC510. The SWC510 is now in programming mode for 3 minutes. c. When in the programming mode, press the programming button on the SWC441 until a confirmation (the curtain shifts) is received.
2. Setting the sun threshold Use the tool provided to turn the sun threshold regulator to the desired setting. The sun threshold has 15 possible settings (approx. 2 klux to 100 klux). When slowly turning the regulator, the curtain shifts to indicate the setting changes. 3. Setting the wind threshold Use the tool provided to turn the wind threshold regulator to the desired setting. The wind threshold has 11 possible settings (approx. 2 m/s to 22 m/s).
SWS441/SWS641 control set Commissioning the radio-controlled Sun-Wind-Set with handheld transmitter and SWS441/SWS641 sensor 1. Programming the master transmitter 2 x click Switch off the power supply on the radio receiver (drive type PSF(+)) and then switch it back on . Press the programming button on the master transmitter until the drive clicks twice . Note: Follow the instructions on pages 52 and 53 to set the limit positions for the PSF(+) drive. 2.
3. Setting the sun threshold Use the tool provided to turn the sun threshold regulator to the desired setting. The sun threshold has 15 possible settings (approx. 2 klux to 100 klux). When slowly turning the regulator, the tubular drive clicks to indicate the setting changes. 4. Setting the wind threshold Use the tool provided to turn the wind threshold regulator to the desired setting. The wind threshold has 11 possible settings (approx. 2 m/s to 22 m/s).
SC211 control Commissioning the motion sensor for awnings SC211 1. Programming the master transmitter 2 x click Switch off the power supply on the radio receiver (drive type PSF(+)) and then switch it back on . Press the programming button on the master transmitter SWC241 until the drive clicks twice . Note: Follow the instructions on pages 52 and 53 to set the limit positions for the PSF(+) drive. 2. Programming the SC211 1 x click a.
3. Setting the wind threshold Use the tool provided to turn the wind threshold regulator at the SWC241 to the desired setting. The wind threshold has 11 possible settings (approx. 2 m/s to 22 m/s). When slowly turning the regulator, the tubular drive clicks to indicate the setting changes. 4. Setting the release angle Use the tool provided to set the release angle on the rotary switch of the PCB. 0 = Off 1 = Sensitive 9 = Insensitive Move the awning to the extending limit position.
Important safety instructions Caution! Failure to observe these instructions can lead to serious injuries. Important safety instructions for handling tubular drives. • • • • • • • • • • • • • • • • • • • • • • • • Do not allow children to play with control units. When electrical or electronic equipment and units are operated, certain components, e.g., the power supply unit, are live.
• • • • • • • • • Disconnect the connecting cable from the power prior to installation. Always comply with regulations of local energy supply companies and VDE 100 provisions for wet and damp rooms during installation. Keep people out of the system’s range of movement. Only use in dry rooms (exceptions: VCJ470, VC410, VC510, SWC510). Only use original, unmodified Becker parts. Observe the country-specific regulations. Dispose of exhausted batteries properly. Only replace batteries with the same type.
BECKER-Antriebe GmbH Friedrich-Ebert-Str. 2-4 35764 Sinn, Germany Tel.: +49 (0) 27 72/507-0 Fax: +49 (0) 27 72/507-110 4995 900 070 1 Version: 01/2009 info@becker-antriebe.com www.becker-antriebe.