Noise with external power amplifier (end stage)
Fault: Noise can be heard in conjunction with an external power amplifier.
Possible solutions:
Use the line-out rather than the loudspeaker output connections for output to the external power amplifier.
Correct setting of the sensitivity of the power amplifier at the unit's output.
Set the input level of the amplifier to approx. 3 Volt (3000mV) for this purpose.
In the case of a sensitive power amplifier input (e.g. 100mV) where no level adjustment is possible, an attenuator
must be interposed.
Echo during phone calls
Fault: The other party hears an echo during phone calls.
Solution: Set the sensitivity of the hands-free microphone (see Operating Guide, under User Menu). In most cases, a
setting between 0 and 3 achieves an optimum result.