User Manual

Note: When the display panel powered by battery, after 20 seconds of no
operation, the LED screen would turn off and enter to the energy-saving state,
the APP will be locked, click on the APP to unlock the APP; To wake up the
display again ,press .
5. Programming Set:
WiFi version can be set in APP.
Non-wifi version, press 4 times to enter the programming mode setting. At
this time, the screen displays (MON.TUE.WED.THU.FRI), the "minute" of the time
flashes, and the period 1 . Press again to select and set the hour,
temperature, and period. Press / to adjust the corresponding value.
Press once more to confirm and exit.
4. Time Set: press to enter time setting, press / to adjust the value,
respectively for minutes, hours, and days (the screen displays "1" for Monday, "2"
means Tuesday, and so on) for setting. After the adjustment is complete,
press to exit the time setting
WiFi version, the local network time will be automatically synchronized when
connecting to the network for the first time.
3. Temp. Set: Press / to set the temperature. Only in manual mode, the
temperature can be set arbitrarily.
2、Manual & programming mode:Press to switch manual mode and
programming mode .
Manual mode: the user sets the temperature by himself;
Programming mode: The thermostat will control the temperature according to
the preset value. See "Programming Set" for details.
BHT-8000RF Wireless Thermostat
Thank you for choosing our products!
IN THE BOX YOU WILL FIN D
Display panel*1 Receiver*1 Bracket*1
Screw*2 QC passed*1 Manual*1 USB*1
ABOUT YOUR THERMOSTAT
BHT-8000RF is suitable for electric heating, water heating, wall-hung
boilers and boiler temperature control systems.
It can be used in smart homes, shopping malls and industrial sites.
Before use, please confirm the specific model of this product and the
corresponding heating equipment.
Please refer to the wiring diagram to identify the model or contact the
merchant.
Note: The USB and Battery could not supply power in the same time
,you could only select only one of them.
FEATURES
1. No need cassette or punch for installation;
2. Move LED panel can be moved at your will;
3. Temperature control accuracy (±0.5℃);
4. Support power-off protection, data will not be lost
5. Programming mode, 6 periods a day. Programmable setting, ECO,
cost-saving, smarter and more environmentally friendly;
6. Support:
Tmall, Amazon echo, Google Home, Yandex Alice,
Xiaomi Smart, Xiaodu Smart;
MODEL DEFINITION
GA: Water heating, 5A
GB: Electric floor Heating, 16A
GC: Water/Gas Boiler, 5A
GBC:Electric floor Heating, 16A & Water/Gas Boiler, 5A
W: Support APP wifi control
Example:
BHT-8000RF-GAW
TECHNICAL DATA
DIMENSION
BEFORE WIRING AND INSTALLING
Unit: mm
130.0
90.0
17.5
60.0
1. Be sure it is suitable for your heating equipment before installation;
2. Be sure to keep the power off before installation or maintenance;
3. Please strictly follow the wiring diagram for wiring installation;
4. When installing to the wall, make sure it is fastened
5. Do not pull the cable hard, it may damage the product;
6. When using a hard plastic wire ,please bend it to an appropriate angle ;
7. Only Professionals recommended;
8. Please contact the after-sales service for equipment failure, do not
repair it yourself;
9. After installation, please refer to this manual to check again to ensure
normal safety
WIRING
INSTALLATION
HOME SCREEN QUICK REFERENCE
1. The wifi version can display weather information. When it is frist time
connected wifi, the weather data is uploaded to the thermostat after it
working for 3-4 minutes. The weather would be updated every 30 minutes
after connecting to wifi。
2. When WiFi connected,click the / button to display the current humidity
in the upper left corner
DISPLAY PANEL OPERATION
When the display panel is powered by USB, the APP will not be locked.
The display panel uses 2*AA for power supply. If the battery voltage is insufficient,
the screen will display a icon. Please replace the battery in time.
The display panel power-off and receiver quick power-off are independent of
each other.
Default settings for program schedule:
Setting the Functions and Options
When the display panel is off , press and at the same time for 5
seconds to enter the advanced selection setting. Press to select the
function, press or to adjust the corresponding value. All advanced
option settings will take effect automatically after restarting the thermostat.
LED panel installation steps:
1. Remove the battery cover
2. Install two 5A batteries
3. Install the battery cover
4. Fix the traceless hook on the wall ,then hang the product
2
1
3
4
Outdoor humidity
Unfreezing Weather
Period
Week
Temp.Display
Programming
Manual
DownUpPower
on/off
Mode Clock
Outdoor wind speeds
Set Temp.
Low battery warning
RoomTemp.
Heating
Time
display
MON.-FRI.
(①②③④⑤ shows
on scteen)
SAT.
(⑥shows on scteen)
SUN.
(⑦shows on scteen)
TEMP. TEMP. TEMP.
TIMETIMETIME
Receiver
Power Supply
95~240 V AC,
50~60 Hz
Receiver
Current Load
5 A(water heating/
waterboiler/gas boiler);
16 A(electric heating)
Sensor NTC3950,10KTemp. Error ±1℃
Timing Error <1%
Set Temp.
Range
5~45℃
Working
Ambient Temp/
Humidity
0~45℃,5~95% RH
(Non Condensing)
Power
consumption
<1.5W
LED Panel
Material
PC+ABS(Fireproof)
Protection Class
IP20
Buttons
Capacitive Touch
Buttons
Screen
LED
Receiver
Installation
Wall-mounted
LED Panel
power supply
2*AA battery/USB
Temperature
control accuracy
0.5℃
RECEIVER OPERATION
1. Power: Press the "left button" to control the receiver on/off. When the
Power light is on, it means it is turned on, otherwise it is turned off.
2. When the receiver is turned
on, press and hold the "right button" to enter
the code matching between the display panel and the receiver. At this time,
IP Seting flashes red, see the following "Setting the Functions and
Options" for details
When the receiver is off, long press the "right button", the receiver enters
the Wi-Fi network configuration state, the Wi-Fi light will flash quickly
(AP mode) or the Wi-Fi light will display slowly (EP mode), see the wifi
connection process below for details.
RECEIVER
99.0
86.0
24.2
60.0
Power
Load
Wifi
IP
Seting
RF
Suitable for electric heating/water heating/wall-hung boiler/boiler
Electrical Shock or Equipment Damage Hazard,
can shock individuals or short equipment
circuitry.Disconnect power supply
before installation.
CAUTION
Note:
Item 1.2.3 of Setting the Functions and Options is the code matching
connection setting of the display panel and the receiver.
Code matching connection steps: 1. The first item is set to 1; the second item
is the serial number of the thermostat 0-99, as long as the serial numbers of
the two thermostats are different; the third item does not need to be set.
After the display panel completes the above operations, when the receiver is
turned on, press and hold the right button for 5 seconds, and the IP Seting
flashes red light to indicate the start of code matching, and the steady red
light indicates that the code matching is completed.
Then check the 3rd item of the advanced options on the display panel, and
1 is displayed, indicating that the code is matched successfully.
Code Function Default
Code confirmation
Device ID
Code Matching
Succeeded
Temperature
compensation
Deadzone Temp.
Min.Set Temp.
Max.Set Temp.
Standby
Brightness
Energy saving
Mode
Energy saving
Temp.
Restore factory
settings
Version NO.
1
0
2
0
3
4
2
5
1
6
5℃
7
35℃
8
0
9
0
10
20
11
0
12
U1 start number,
U1... UA... UF
Setting and options
00:No code matching
01:start code matching
0-99
only reading.
00: code matching failed
01: code matching succeed
-9~9℃
1~5℃
5~15℃
15~35℃
0~7
00:OFF
01:ON
5~30℃
00: normal mode,
01: factory mode
1. Power: Press the to turn on/off of the LED display panel.
6:00~8:00 20 20 20
8:00~11:30 15 20 20
11:30~13:00 15 20 20
13:30~17:00 15 20 20
17:00~22:00 22 20 20
22:00~6:00 15 15 15
6:00~8:00
8:00~11:30
11:30~13:00
13:30~17:00
17:00~22:00
22:00~6:00
6:00~8:00
8:00~11:30
11:30~13:00
13:30~17:00
17:00~22:00
22:00~6:00
Period 1
Period 2
Period 3
Period 4
Period 5
Period 6
L
N
Dry Contact
L
N
L1
N1
LOAD
L
N
N1
Open
16A
L2
M
GA GB GC
M
M
GAB GBC GAC
Note: Only for normally closed valves
Power supply: 95~220V, 50/60Hz;
maximum load : 16A ,for electric heating film, cable, tile.
maximum load : 3A, for water valve actuator ;
maximum load : 3A, for wall-hung boiler;
Close
L
N
N1
Open
L2
Close
L
N
L1
N1
LOAD
16A
Dry Contact
Dry Contact
Close
L
N
N1
L1
DISPLAY PANEL
Standby Brightness: ( recommend Max 4 ,if too high ,the LED light would
damager , and the LED life time would ne short)

Summary of content (2 pages)