User's Manual

bebob factory GmbH Höglwörtherstr. 350 – D-81379 München Tel.: +49 89 27818282
www.bebob.de
October 2018
Discharging
Maximum load is 10.0A. When using the battery with video or lighting equipment, power
consumption of the equipment must be 10.0A or below. For the protection of the battery, a
load of 10.0A or over may activate the internal protection circuit and stop supply of power.
In this case the status led will turn red.
The battery can be used in ambient temperature of - 20°C - + 55°C.
Storage
Storage temperature range is - 20°C ~ + 35°C (<85% humidity).
To store the battery for a long period (longer than 4 Weeks), the battery should be charged
between 50% and 75%. The battery should be recharged every 4 Weeks.
After storage some self-discharge will occur. Before re-use it is advisable to recharge the
battery fully.
Camera Data Communication
Blue leds: Arri/Sony Data Protocol
Red leds: Red Data Protocol
To switch between both status, press the Check button for 5s
Status led
Status led lighting Green: Full Capacity over 70% of New
Status led lighting Yellow: Full Capacity between 50% and 70% of New
Status led lighting Red: Full Capacity under 50% of New
Flash Light
To switch On/Off press the Check Button Twice