Specifications
TRP-C24H
Isolated 16-channel Open Collector
Modbus TCP Module
Ethernet Remote IO
TRP-C24H an Isolated open collector digital outputs
Modbus TCP Module, provides 16 channels that allow
you output open collector signal (100mA) to driven
your devices on network, it supports 3 communication
protocol, TRP-ASCII, Modbus RTU / ASCII, TRP-
C24H can be easy and convenient to use application
supports Modbus. Software engineers can use the
TRP-ASCII or Modbus RTU command set quickly and
easily integrated into the self-development program,
such as Microsoft VB, VC... The TRP-C24H built-in
independent IP, WEB-browsing more convenient to
rewrite the configuration and collect information
through computers, tablet computers, smart phones,
will be available! TRP-C24H built-in watchdog
function to ensure the normal operation of the module,
and a built-in voltage monitoring to ensure that the
boot, excellent and advanced hardware for harsh
environment. TRP-C24H with TRP-C26H, 16 remote
control directly, do not need to run the software and
equipment. TRP-C24H also offers the maximum
connection 16 host client to link the network server
that is easy to operate in Modscan32 ,Modbus
Poll,CAS Modbus Scanner and SCADA ...application
uses TCP mode and Virtual-COM mode.
Wide input range DC power supply.
Automatically determine 3 TRP-ASCII and Modbus
RTU/ASCII communication protocol.
16 TCP Port can be open at the same time.
Heart Beat function ensures a reliable
communicating connection.
Support Virtual-COM mode.
IO status can be set in the boot!
WEB PAGE can be directly output and read IO
status.
Easily update the firmware using the Internet.
Back to factory configuration by external touch
Button.
Auto reconnection when power or Ethernet fail.
Digital output signal with 3750Vrms isolation
protection.
Built-In watchdog function prevents system boot fail.
LED for each I/O channels working status.
Support Auto-MDIX twisted pair crossover detection
and Auto-Correction.
Power Input Voltage DC +10V to +30V.
Protocol: TRP-ASCII and Modbus RTU/ASCII.
Digital output maximum voltage:+30V.
Digital output maximum current: 100mA.
Digital output isolation: 3750Vrms.
Communication interface: Ethernet RJ45.
Configuration mode: Trycom Device Manager, WEB settings.
Matching remote control: with TRP-C26H.
Heart Beat: TCP Port sent string every 5 seconds.
TCP Maximum Connection:1~16.
Module ID :1~255.
Connection type: Screw terminal for maximum AWG 12 wire.
Power supply: Screw terminal, or external DC adapter.
Power consumption 240mA/12V.
Operating environment: 0 to 50℃.
Storage temperature:. -10 to 70℃.
Humidity: 10~90% Non-condensing.
Dimension: 151mm X 75mm X 26mm .
Weight: 395g .
21
Power/Link/16 CH DO LED indicator.
DIN-Rail and panel mount support.
Dual power input select from screw terminal or DC-Jack.