User's Guide

Table Of Contents
AT commands Serial interfacing commands
XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
87
Parameter Description
0x5 38400 b/s
0x6 57600
0x7 115200 b/s
0x8 230400 b/s
Default
0x03 (9600 b/s)
NB (Parity)
Set or read the serial parity settings for UART communications.
The device does not actually calculate and check the parity. It only interfaces with devices at the
configured parity and stop bit settings.
Parameter range
0x00 - 0x04
Parameter Description
0x00 No parity
0x01 Even parity
0x02 Odd parity
0x03
Mark parity (forced high)
Default
0x00
RO (Packetization Timeout)
Set or read the number of character times of inter-character silence required before transmission
begins when operating in Transparent mode. RF transmission will also commence when the maximum
payload (see Maximum payload) is received in the DI buffer.
Set RO to 0 to transmit characters as they arrive instead of buffering them into one RF packet.
Parameter range
0 - 0xFF (x character times)
Default
3
D7 (DIO7/CTS)
Sets or displays the DIO7/CTS configuration (TH pin 12/SMT pin 25).