User's Guide
Table Of Contents
- XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
- Technical specifications
- Hardware
- Configure the XBee/XBee-PRO S2C 802.15.4 RF Module
- Modes
- Operation
- AT commands
- Special commands
- Networking and security commands
- C8 (802.15.4 Compatibility)
- CH (Operating Channel)
- ID (Network ID)
- DH (Destination Address High)
- DL (Destination Address Low)
- MY (Source Address)
- SH (Serial Number High)
- SL (Serial Number Low)
- MM (MAC Mode)
- RR (XBee Retries)
- RN (Random Delay Slots)
- ND (Network Discovery)
- NT (Node Discover Timeout)
- NO (Node Discovery Options)
- DN (Discover Node)
- CE (Coordinator Enable)
- SC (Scan Channels)
- SD (Scan Duration)
- A1 (End Device Association)
- A2 (Coordinator Association)
- AI (Association Indication)
- DA (Force Disassociation)
- FP (Force Poll)
- AS (Active Scan)
- ED (Energy Detect)
- EE (Encryption Enable)
- KY (AES Encryption Key)
- NI (Node Identifier)
- NP (Maximum Packet Payload Bytes)
- RF interfacing commands
- Sleep commands
- Serial interfacing commands
- I/O settings commands
- D0 (DIO0/AD0)
- D1 (DIO1/AD1)
- D2 (DIO2/AD2)
- D3 (DIO3/AD3)
- D4 (DIO4)
- D5 (DIO5/ASSOCIATED_INDICATOR)
- D8 (DIO8/SLEEP_REQUEST)
- P0 (RSSI/PWM0 Configuration)
- P1 (PWM1 Configuration)
- P2 (SPI_MISO)
- M0 (PWM0 Duty Cycle)
- M1 (PWM1 Duty Cycle)
- P5 (SPI_MISO)
- P6 (SPI_MOSI Configuration)
- P7 (SPI_SSEL )
- P8 (SPI_SCLK)
- P9 (SPI_ATTN)
- PR (Pull-up/Down Resistor Enable)
- PD (Pull Up/Down Direction)
- IU (I/O Output Enable)
- IT (Samples before TX)
- IS (Force Sample)
- IO (Digital Output Level)
- IC (DIO Change Detect)
- IR (Sample Rate)
- RP (RSSI PWM Timer)
- I/O line passing commands
- Diagnostic commands
- Command mode options
- Operate in API mode
- API mode overview
- API frame specifications
- Escaped characters in API frames
- Frame descriptions
- TX Request: 64-bit address frame - 0x00
- TX Request: 16-bit address - 0x01
- AT Command frame - 0x08
- AT Command - Queue Parameter Value frame - 0x09
- Remote AT Command Request frame - 0x17
- RX Packet: 64-bit Address frame - 0x80
- Receive Packet: 16-bit address frame - 0x81
- RX (Receive) Packet: 64-bit address IO frame- 0x82
- RX Packet: 16-bit address I/O frame - 0x83
- AT Command Response frame - 0x88
- TX Status frame - 0x89
- Modem Status frame - 0x8A
- Remote Command Response frame - 0x97
- Regulatory information
- Load 802.15.4 firmware on ZB devices
- Migrate from XBee through-hole to surface-mount devices
- PCB design and manufacturing
AT commands Networking and security commands
XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
76
PANs. If you set the ReassignChannel option, SD determines how long the coordinator performs an
Energy Scan to determine which channel it will operate on.
End Device: Duration of Active Scan during Association. In a Beacon system, set SD=BE of the
coordinator. SD must be set at least to the highest BE parameter of any Beaconing Coordinator with
which an end device or coordinator wants to discover.
Scan Time is measured as:
([# of channels to scan] * (2 ^SD) * 15.36 ms) + (38 ms * [# of channels to scan]) + 20 ms
Use the SC (Scan Channels) command to set the number of channels to scan. The XBee can scan up to
16 channels (SC = 0xFFFF). The XBee-PRO can scan up to 13 channels (SC= 0x1FFE).
SD influences the time the MAC listens for beacons or runs an energy scan on a given channel.
Example
The following table shows the results for a thirteen channel scan.
SD setting Time
0 0.18 s
2 0.74 s
4 2.95 s
6 11.80 s
8 47.19 s
10 3.15 min
12 12.58 min
14 50.33 min
Parameter range
0 - 0x0F (exponent)
Default
4
A1 (End Device Association)
Sets or displays the End Device association options.
Parameter range
0 - 0x0F (bit field)
Bit field: