User's Guide
Table Of Contents
- XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
- Technical specifications
- Hardware
- Configure the XBee/XBee-PRO S2C 802.15.4 RF Module
- Modes
- Operation
- AT commands
- Special commands
- Networking and security commands
- C8 (802.15.4 Compatibility)
- CH (Operating Channel)
- ID (Network ID)
- DH (Destination Address High)
- DL (Destination Address Low)
- MY (Source Address)
- SH (Serial Number High)
- SL (Serial Number Low)
- MM (MAC Mode)
- RR (XBee Retries)
- RN (Random Delay Slots)
- ND (Network Discovery)
- NT (Node Discover Timeout)
- NO (Node Discovery Options)
- DN (Discover Node)
- CE (Coordinator Enable)
- SC (Scan Channels)
- SD (Scan Duration)
- A1 (End Device Association)
- A2 (Coordinator Association)
- AI (Association Indication)
- DA (Force Disassociation)
- FP (Force Poll)
- AS (Active Scan)
- ED (Energy Detect)
- EE (Encryption Enable)
- KY (AES Encryption Key)
- NI (Node Identifier)
- NP (Maximum Packet Payload Bytes)
- RF interfacing commands
- Sleep commands
- Serial interfacing commands
- I/O settings commands
- D0 (DIO0/AD0)
- D1 (DIO1/AD1)
- D2 (DIO2/AD2)
- D3 (DIO3/AD3)
- D4 (DIO4)
- D5 (DIO5/ASSOCIATED_INDICATOR)
- D8 (DIO8/SLEEP_REQUEST)
- P0 (RSSI/PWM0 Configuration)
- P1 (PWM1 Configuration)
- P2 (SPI_MISO)
- M0 (PWM0 Duty Cycle)
- M1 (PWM1 Duty Cycle)
- P5 (SPI_MISO)
- P6 (SPI_MOSI Configuration)
- P7 (SPI_SSEL )
- P8 (SPI_SCLK)
- P9 (SPI_ATTN)
- PR (Pull-up/Down Resistor Enable)
- PD (Pull Up/Down Direction)
- IU (I/O Output Enable)
- IT (Samples before TX)
- IS (Force Sample)
- IO (Digital Output Level)
- IC (DIO Change Detect)
- IR (Sample Rate)
- RP (RSSI PWM Timer)
- I/O line passing commands
- Diagnostic commands
- Command mode options
- Operate in API mode
- API mode overview
- API frame specifications
- Escaped characters in API frames
- Frame descriptions
- TX Request: 64-bit address frame - 0x00
- TX Request: 16-bit address - 0x01
- AT Command frame - 0x08
- AT Command - Queue Parameter Value frame - 0x09
- Remote AT Command Request frame - 0x17
- RX Packet: 64-bit Address frame - 0x80
- Receive Packet: 16-bit address frame - 0x81
- RX (Receive) Packet: 64-bit address IO frame- 0x82
- RX Packet: 16-bit address I/O frame - 0x83
- AT Command Response frame - 0x88
- TX Status frame - 0x89
- Modem Status frame - 0x8A
- Remote Command Response frame - 0x97
- Regulatory information
- Load 802.15.4 firmware on ZB devices
- Migrate from XBee through-hole to surface-mount devices
- PCB design and manufacturing
Operate in API mode Frame descriptions
XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
118
Receive Packet: 16-bit address frame - 0x81
Description
When the device receives an RF packet from a device configured to use 16 bit addressing (MY < FFFE),
it sends this frame out the serial interface.
Format
The following table provides the contents of the frame. For details on frame structure, see API frame
specifications.
Frame data
fields Offset Description
Frame type 3 0x81
Source
address
4-5
MSB first
LSB last
RSSI 6
RSSI = hexadecimal equivalent of -dBm value. For example, if RX signal
strength = -40 dBm, it returns 0x28 (40 decimal).
Options 7
Bit 0 = [reserved]
Bit 1 = Address broadcast
Bit 2 = PAN broadcast
Bits 3 - 7 = [reserved]
RF data 8-n The RF data length can be up to 116 bytes, but may be less depending on
other factors discussed in
Maximum payload
.