User's Guide
Table Of Contents
- XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
- Technical specifications
- Hardware
- Configure the XBee/XBee-PRO S2C 802.15.4 RF Module
- Modes
- Operation
- AT commands
- Special commands
- Networking and security commands
- C8 (802.15.4 Compatibility)
- CH (Operating Channel)
- ID (Network ID)
- DH (Destination Address High)
- DL (Destination Address Low)
- MY (Source Address)
- SH (Serial Number High)
- SL (Serial Number Low)
- MM (MAC Mode)
- RR (XBee Retries)
- RN (Random Delay Slots)
- ND (Network Discovery)
- NT (Node Discover Timeout)
- NO (Node Discovery Options)
- DN (Discover Node)
- CE (Coordinator Enable)
- SC (Scan Channels)
- SD (Scan Duration)
- A1 (End Device Association)
- A2 (Coordinator Association)
- AI (Association Indication)
- DA (Force Disassociation)
- FP (Force Poll)
- AS (Active Scan)
- ED (Energy Detect)
- EE (Encryption Enable)
- KY (AES Encryption Key)
- NI (Node Identifier)
- NP (Maximum Packet Payload Bytes)
- RF interfacing commands
- Sleep commands
- Serial interfacing commands
- I/O settings commands
- D0 (DIO0/AD0)
- D1 (DIO1/AD1)
- D2 (DIO2/AD2)
- D3 (DIO3/AD3)
- D4 (DIO4)
- D5 (DIO5/ASSOCIATED_INDICATOR)
- D8 (DIO8/SLEEP_REQUEST)
- P0 (RSSI/PWM0 Configuration)
- P1 (PWM1 Configuration)
- P2 (SPI_MISO)
- M0 (PWM0 Duty Cycle)
- M1 (PWM1 Duty Cycle)
- P5 (SPI_MISO)
- P6 (SPI_MOSI Configuration)
- P7 (SPI_SSEL )
- P8 (SPI_SCLK)
- P9 (SPI_ATTN)
- PR (Pull-up/Down Resistor Enable)
- PD (Pull Up/Down Direction)
- IU (I/O Output Enable)
- IT (Samples before TX)
- IS (Force Sample)
- IO (Digital Output Level)
- IC (DIO Change Detect)
- IR (Sample Rate)
- RP (RSSI PWM Timer)
- I/O line passing commands
- Diagnostic commands
- Command mode options
- Operate in API mode
- API mode overview
- API frame specifications
- Escaped characters in API frames
- Frame descriptions
- TX Request: 64-bit address frame - 0x00
- TX Request: 16-bit address - 0x01
- AT Command frame - 0x08
- AT Command - Queue Parameter Value frame - 0x09
- Remote AT Command Request frame - 0x17
- RX Packet: 64-bit Address frame - 0x80
- Receive Packet: 16-bit address frame - 0x81
- RX (Receive) Packet: 64-bit address IO frame- 0x82
- RX Packet: 16-bit address I/O frame - 0x83
- AT Command Response frame - 0x88
- TX Status frame - 0x89
- Modem Status frame - 0x8A
- Remote Command Response frame - 0x97
- Regulatory information
- Load 802.15.4 firmware on ZB devices
- Migrate from XBee through-hole to surface-mount devices
- PCB design and manufacturing
Operate in API mode Frame descriptions
XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
116
Remote AT Command Request frame - 0x17
Description
Used to query or set device parameters on a remote device. For parameter changes on the remote
device to take effect, you must apply changes, either by setting the Apply Changes options bit, or by
sending an AC command to the remote.
Format
The following table provides the contents of the frame. For details on frame structure, see API frame
specifications.
Frame data
fields Offset Description
Frame type 3 0x17
Frame ID 4
Identifies the data frame for the host to correlate with a subsequent ACK
(0x97). If set to 0, the device does not send a response.
64-bit
destination
address
5-12
MSB first, LSB last. Set to the 64-bit address of the destination device.
If the 16-bit parameter has a different value from 0xFFFE the device uses
the 64-bit address is used. Otherwise, it uses the 16-bit address.
16-bit
destination
address
13-14
MSB first, LSB last. Set to match the 16-bit network address of the
destination device, if known.
Set to 0xFFFE if the address is unknown, or if sending a broadcast.
AT command
16-17
Command name: two ASCII characters that identify the command.
Command
parameter
18-n If present, indicates the parameter value you request for a given register.
If no characters are present, it queries the register.