User's Guide

Table Of Contents
AT commands Command mode options
XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
104
Parameter range
0 - 0xFFFFFFFF
Default
0x10000
Command mode options
The following commands are Command mode option commands.
CT (Command mode Timeout)
Sets or displays the Command mode timeout parameter. If a device does not receive any valid
commands within this time period, it returns to Idle mode from Command mode.
Parameter range
2 - 0x1770 (x 100 ms)
Default
0x64 (10 seconds)
CN (Exit Command mode)
Exits Command mode and returns the product family to Idle mode.
Parameter range
N/A
Default
N/A
AC (Apply Changes)
Immediately applies new settings without exiting Command mode.
Applying changes means that the device is re-initialized based on changes made to its parameter
values. Once changes are applied, the device immediately operates according to the new parameter
values.
This behavior is in contrast to issuing the WR (Write) command. The WR command saves parameter
values to non-volatile memory, but the device still operates according to previously saved values until
the device is rebooted or the CN (Exit AT Command Mode) or AC commands are issued. For more
information, see AT Command - Queue Parameter Value frame - 0x09.
Parameter range
N/A
Default
N/A