User's Guide
Table Of Contents
- XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
- Technical specifications
- Hardware
- Configure the XBee/XBee-PRO S2C 802.15.4 RF Module
- Modes
- Operation
- AT commands
- Special commands
- Networking and security commands
- C8 (802.15.4 Compatibility)
- CH (Operating Channel)
- ID (Network ID)
- DH (Destination Address High)
- DL (Destination Address Low)
- MY (Source Address)
- SH (Serial Number High)
- SL (Serial Number Low)
- MM (MAC Mode)
- RR (XBee Retries)
- RN (Random Delay Slots)
- ND (Network Discovery)
- NT (Node Discover Timeout)
- NO (Node Discovery Options)
- DN (Discover Node)
- CE (Coordinator Enable)
- SC (Scan Channels)
- SD (Scan Duration)
- A1 (End Device Association)
- A2 (Coordinator Association)
- AI (Association Indication)
- DA (Force Disassociation)
- FP (Force Poll)
- AS (Active Scan)
- ED (Energy Detect)
- EE (Encryption Enable)
- KY (AES Encryption Key)
- NI (Node Identifier)
- NP (Maximum Packet Payload Bytes)
- RF interfacing commands
- Sleep commands
- Serial interfacing commands
- I/O settings commands
- D0 (DIO0/AD0)
- D1 (DIO1/AD1)
- D2 (DIO2/AD2)
- D3 (DIO3/AD3)
- D4 (DIO4)
- D5 (DIO5/ASSOCIATED_INDICATOR)
- D8 (DIO8/SLEEP_REQUEST)
- P0 (RSSI/PWM0 Configuration)
- P1 (PWM1 Configuration)
- P2 (SPI_MISO)
- M0 (PWM0 Duty Cycle)
- M1 (PWM1 Duty Cycle)
- P5 (SPI_MISO)
- P6 (SPI_MOSI Configuration)
- P7 (SPI_SSEL )
- P8 (SPI_SCLK)
- P9 (SPI_ATTN)
- PR (Pull-up/Down Resistor Enable)
- PD (Pull Up/Down Direction)
- IU (I/O Output Enable)
- IT (Samples before TX)
- IS (Force Sample)
- IO (Digital Output Level)
- IC (DIO Change Detect)
- IR (Sample Rate)
- RP (RSSI PWM Timer)
- I/O line passing commands
- Diagnostic commands
- Command mode options
- Operate in API mode
- API mode overview
- API frame specifications
- Escaped characters in API frames
- Frame descriptions
- TX Request: 64-bit address frame - 0x00
- TX Request: 16-bit address - 0x01
- AT Command frame - 0x08
- AT Command - Queue Parameter Value frame - 0x09
- Remote AT Command Request frame - 0x17
- RX Packet: 64-bit Address frame - 0x80
- Receive Packet: 16-bit address frame - 0x81
- RX (Receive) Packet: 64-bit address IO frame- 0x82
- RX Packet: 16-bit address I/O frame - 0x83
- AT Command Response frame - 0x88
- TX Status frame - 0x89
- Modem Status frame - 0x8A
- Remote Command Response frame - 0x97
- Regulatory information
- Load 802.15.4 firmware on ZB devices
- Migrate from XBee through-hole to surface-mount devices
- PCB design and manufacturing
AT commands Diagnostic commands
XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
103
Default
Set in firmware
DB (Last Packet RSSI)
Reports the RSSI in -dBm of the last received RF data packet. DB returns a hexadecimal value for the -
dBm measurement.
For example, if DB returns 0x60, then the RSSI of the last packet received was -96 dBm.
If the XBee/XBee-PRO S2C 802.15.4 RF Module has been reset and has not yet received a packet, DB
reports 0.
This value is volatile (the value does not persist in the device's memory after a power-up sequence).
Parameter range
0 - 0xFF [read-only]
Default
N/A
EC (CCA Failures)
ReSets or displays the count of Clear Channel Assessment (CCA) failures. This register increments
when the device does not transmit a packet because it detected energy above the CCA threshold level
set with CA command. This count saturates at its maximum value. Set the count to zero to reset the
count.
Parameter range
0 - 0xFFFF
Default
N/A
EA (ACK Failures)
Resets or displays the count of acknowledgment failures. This register increments when the device
expires the retries without receiving an ACK on a packet transmission. This count saturates at its
maximum value. Set the count to zero to reset the count.
Parameter range
0 - 0xFFFF
Default
N/A
DD (Device Type Identifier)
Stores the Digi device type identifier value. Use this value to differentiate between multiple XBee
devices.
If you change DD, RE (Restore Defaults) will not restore defaults. The only way to get DD back to