Specifications
IsatDock MARINE
Quick Start Guide
Suitable for the IsatPhone Pro
www.beamcommunications.com
PART #: USRQSG006201
BEAM Communications Pty Ltd
8 Anzed Court, Mulgrave
Victoria, 3170, AUSTRALIA
Web: www.beamcommunications.com
Information: info@beamcommunications.com
Support: support@beamcommunications.com
Tel: +61 3 8588 4500
Fax: +61 3 9560 9055
2. Specication Summary
Average Power
Consumption
Current @ 12V
Average Watts
Power w/o IsatPhone
Pro
130mA 1.6W
Standby + Charging 360mA 4.3W
Transmit + Charging 875mA 10.5W
Sleep Mode 5mA 60mW
Peak Current 3.5 A 42W
Physical Specications
Dimensions 270 x 189 x 101
(mm)
10.6 x 7.4 x 4
(inches)
Weight - dock 1665g 3.67lbs
Total Kit Weight 2715g 5.99lbs
Environment Specications
Operating Range -30
o
C to +70
o
C -22
o
F to +158
o
F
Storage -35
o
C to +85
o
C -31
o
F to +185
o
F
Battery Carging Temp* 0
o
C to +45
o
C +32
o
F to 113
o
F
Humidity <= 75% RH
GPS Module (internal)
Channels 14 tracking, 51 channel acquiring
Update Rate 1Hz
Accuracy Position 2.5m CEP, Velocity 0.1m/s,
Timing 300ns
Acquisition TTFF Cold 30sec, Hot 1sec
Sensitivity -161 dBm
Operational Limits Altitude 18000m, Velocity 515m/s
Connectors / Interfaces
POTS/RJ11 RJ11/2-wire, 5REN @ 600m
Adjustable dial, ring, busy tone
congured frequency and adaptive
impedance.
Inmarsat Antenna TNC-Female
GPS Antenna SMA-Female
10-32V DC 4-way microFit
(AC/DC adaptor, or DC lead)
Privacy Handset Port RJ9 connector
Conguration/Data Micro USB
Speaker phone In-built speaker/microphone
1. IsatDock MARINE Equipment Overview
1. IsatDock MARINE Unit
2. Cover Lock Clasp
3. Marine Cover
4. Mounting Cup
(spring or desk/wall cup options)
5. Privacy Handset
6. Speaker (under handset)
7. Microphone
8. Speaker Phone Button
9. Cover Seal
10. Key lock
11. IsatPhone Pro Eject Button
12. IsatPhone Pro (not included)
13. Function Buttons
14. Status Indication LED
15. Back Panel Connectors
a. USB Data Interface
b. Alert loop connection
c. RJ11/POTS interface
d. DC power and accessory input
3
2
4
5
6
7
8
1
10
9
11
12
13
14
14
c
d
e
b
a
* It is ideal for the ambient temperature to be approximately 18
degrees below the 45
o
C upper limit for the handset to charge
the battery whilst docked.