Technical data
16
The replacement procedure for the lter cartridge is as
follows:
1. Unhook the lower module of the separator by
raising the handle.
2. Extract the lower module of the separator by
allowing it to slide on its wheels with the assistance
of the handle provided.
3. Unscrew the black knob holding the lter cartridge
in position.
4. Extract the lter cartridge.
5. Replace the lter cartridge and repeat the above
operations in the reverse order.
6.4. Cleaning of the lter cartridge (lter)
The lter cartridge should be cleaned/changed at the scheduled intervals (see section 6.1).
CAUTION:
• Before proceeding with replacement operations, a protective mask and gloves must be put on.
• Use only original spare bags by BEAM Electrolux.
• Failure to use these items of personal protection equipment may expose the operator to the risk of
inhalation of dust that is harmful to health, or of the contact of allergenic substances with the skin.
• Before proceeding with replacement operations, the power supply cable must be disconnected.
Failure to comply with this instruction may expose the operator to the risk of accidental system
starting.
• While the dust container is being hooked up, there is the risk of cutting injuries to the ngers.
Dismount the lter cartridge to be cleaned/changed (see details of this operation in previous section),
and if a replacement cartridge is available, use it to replace the cartridge to be cleaned. Clean the
dirty cartridge with the vacuum unit, using the brush accessory for corners, taking care to avoid
damage to the lter fabric. As an alternative, the lter can be washed with water.
If the lter fabric is damaged during cleaning operations, it is essential to replace the cartridge with a
new one.
Use the lter cartridge only when it is completely dry.
After completing any kind of maintenance operation, remember the suction unit must not be restarted
before the lter cartridge is mounted correctly.
6.5. Non-routine maintenance
The manufacturer does not authorize the user of the system to carry out any operations of non-routine
maintenance whatsoever. Contact your local distributor/dealer in case of exceptional events such as:
• Electronics programming
• Breakages
• Overhauls
• Operating cycle modications
Periodic operations Normal frequency
Separator maintenance Every year
Turbine maintenance Every year
Inverter maintenance Every year
Maintenance of self-cleaning compressor Every year