Operating instructions
HUSHPUMP™ 
The HushPump™ is a very quiet, low 
amperage, high flow circulation and filtration 
pump that looks after the filter and heating 
functions of your hot tub. It comes set from the 
factory to operate 24 hours a day. 
Draining Your Beachcomber Hot Tub
Change three to four times a year or more if 
bather load is high. To calculate the change 
frequency, use the following formula.
# DAYS = 1/3 (VOLUME IN US GALLONS) 
MAX # OF DAILY BATHERS
Before draining, check the sanitizer level. It 
should not be above 1.0 to ensure no harm 
is done to the surrounding environment. If 
sanitizer level is high, use Beachcomber’s Neutr-
All as directed on the label. 
1. Turn the power off at the G.F.C.I breaker or 
Power disconnect switch
2. Locate the black drain/fill valve found in 
behind the door on a Portable model or 
under the step on the Protec model. See 
Figure 12. Remove the safety cap from the 
fitting threaded into the valve.
3
.  Attach the female end of your garden hose and 
place the other end at a level lower than the 
drain/fill valve to ensure complete draining. 
Turn the outer part of the drain/fill valve 
counter clockwise to open and start the draining.
4. Draining time will vary from model to 
model.
5. Once the hot tub is drained, disconnect the 
garden hose and close the valve if you are 
not going to fill the hot tub through the 
valve. If you want to fill through this valve, 
unscrew the threaded adapter and thread 
in the male end of your garden hose, then 
attach the female end to your tap and refill.
Vacation Instructions
If leaving your hot tub full and running while on 
vacation for 3-5 days, do the following:
1. Check and adjust pH level if necessary.
2
. 
Shock-treat water to raise sanitizer level. Leave 
the hot tub Heatshield half open for 1 hour.
3. Lower water temperature to minimum 
setting (optional).
4. Lock your Heatshield on the hot tub to 
maintain a safe environment for pets or 
children. If in a high wind area, install 
Hurricane Straps available from your local 
Beachcomber dealership.
Upon returning do the following:
1. Check pH and sanitizer level and adjust if 
necessary.
If leaving for 5-14 days and no one can come by to 
maintain the hot tub do the following:
1. Lower the set temperature to 80ºF/26.5ºC. 
Sanitizers may last longer in cooler water.
2. 
Check and adjust pH and Alkalinity level if 
necessary.
3. Use either a Beachcomber floating tablet 
dispenser or a Holiday Tender tablet 
dispenser to automatically dispense either 
Bromine Disc or Mini Disc in your hot tub 
water to maintain water disinfection. Use the 
low setting on these devices as the demand 
figure 12
23