8
3
1
2
6
X
X
X
X
λ1 λ2 λ3 λ4
λ1
λ2
λ3
λ4
Ex:
Install 1 or 2 virtual push buttons to open the door «manually».
Apply the vitual push button sticker(s) within the optional
field.
Launch a VPB teach-in to configure the detection zone(s).
When the red LED flashes very slowly after 3 seconds, hold
your hand in front of the sticker to learn the detection zone.
The green LED flashes 3x to confirm the selection.
When the red LED flashes again, learn a second (max. 2)
detection zone or wait until the LED switches to green.
3 s
Test the good functioning of the installation before leaving the premises.
FACTORY VALUES
OPTIONAL CONFIGURATION
6.1 VIRTUAL PUSH BUTTON TEACH-IN (VPB)
Make sure the white and yellow wires are connected to the corresponding inputs before configuring the
virtual push buttons.
6.2 ACTIVATING/ DEACTIVATING THE DETECTION CURTAINS
λ1 + λ2 are active
λ3 + λ4 are inactive
curtain is inactive
curtain is active
All curtains are active
The distance between the curtains depends on the mounting height and side. When mounted on the
left, the distance between λ1 and λ4 is approximately 10 cm for every meter (mounting height).
Example: at 5 m the distance between λ1 and λ4 is 50 cm.
LZR-P110 ON SLIDING DOORS
Depending on the needed field depth, activate or deactivate the detection curtains.