User`s guide
75.5753.02 LZR-MICROSCAN 20140107 Page 9 of 12
OVERVIEW OF SETTINGS
MENU LCD DISPLAY PARAMETERS DESCRIPTION
Menu 1 (BASIC)
DoorType
Undefined
Single
Pair
DualEgr
InDualEgr
Type of door system on which sensors are installed
Single: Single Door Pair: Pair of Doors
DualEgr: Dual Egress Doors InDualEgr: Independent Dual Egress Doors
DetectZoneA 24 - 48 Distance (in inches) from sensor LED to leading edge of Door A [round down]
DetectZoneB 24 - 48 Distance (in inches) from sensor LED to leading edge of Door B [round down]
Guiderail 0 - 60 Guiderail height from floor (in inches)
Menu 2 (ADVANCED)
Monitoring
Off
Safe
Stall
Safe&Stall
Act
Act&Stall
Type of monitoring
Off: No Monitoring Safe: Monitoring of Safety Signal
Stall: Monitoring of Stall Signal Safe&Stall: Monitoring of Safety & Stall Signals
Act: Monitoring of Activation Signal Act&Stall: Monitoring of Activation & Stall Signals
KnowingAct
Off
On
Turns Knowing Act Off or On
Act:HoldTime 1 - 5 - 30 Time activation relay will be held after loss of detection (in seconds)
PushNGo
Off
On
Turns Push-And-Go Off or On
NotCloseTime 5 - 30
Time required for door to reach “Closed” from “Open” or “Manual” before switching to
“NotClosed” (in seconds)
AdvanceSafe
Off
On
Type of safety provided while door(s) is/are currently open due to manual operation (or
stack pressure
Off: Allows door(s) to activate, via motion sensor or push plate
On: Prevents door(s) from activating, via motion sensor or push plate
Act:Dist 12 - 24 - 48 Door closed detection distance of Approach Sensor(s) (in inches)
MonitorLogic
ActiveLow
ActiveHigh
ActiveLow: 0V requests monitoring
ActiveHigh: > 0V requests monitoring
Safe:Dist
Deep
Medium
Limited
Door closed detection distance of Safety Sensor(s)
Deep: 4 curtains Medium: 3 curtains Limited: 2 curtains
Menu 3 (DIAGNOSTICS)
DispDoor
Closed
Opening
Open
Closing
NotClosed
Manual
HoldOpen
Off
AdvanceSafe
Displays current position/state of door
DispSens
A1
A2
PP
MO
S1
S2
HM
Displays active devices
A1: Approach microscan 1 A2: Approach microscan 2
PP: Push Plate MO: Motion Sensor
S1: Safety microscan 1 S2: Safety microscan 2
HM: Home Switch Closed
DispPos % % Displays opening position (0% = full closed, 100% = full open relative to learn cycle)
ID#... .................................unique ID number
Config.. .............................configuration part number
Software.. ..........................software part number
ErrorLog. ............................last 20 errors
ZIP. .................... ................all parameter settings in zipped format
HubTemp............................operating temperature of hub
PowerSupply..... .................supply voltage at power connector
OperatingTime....................power duration since first startup
ResetLog... .........................delete all saved errors
Admin.. .............................enter code to access admin mode
Network.............................sensor info: software, configuration, mounting location
NOTES:
Default parameters are in BOLD.
Menu 1 (Basic) items MUST be programmed!