User`s guide

Page 8 of 12 75.5753.02 LZR-MICROSCAN 20140107
SETUP
1 2
3
Program hub according to desired
settings. Menu 1 (Basic) items
MUST be programmed.
Return to home screen.
Push and hold adjustment knob
for three (3) seconds, until blue
LED begins to flash.
4 5a
6
Network icon will appear for
approximately five (5) seconds.
“CLEAR AREA” will display and
countdown will begin. Clear area
around door on both sides.
Automatic teach in will begin with
door closed learn.
7
8
9
Door opening learn. Door will
open automatically.
Door open learn.
Door closing learn.
10
After Teach In is complete a floppy
disk will be displayed.
Hour glass will be displayed for
approximately thirty (30) seconds
while all learn data is saved.
Once Teach In is complete, LCD
displays home screen, Blue LED is
off, and orange LED is on
2
.
11
CAUTION: No safety will be present during the Teach In and Learn cycles.
NOTES:
1: For Dual Egress Reverse Doors, contact BEA Technical Support.
2: Verify Home Switch is “making” and “breaking” by observing orange LED
on hub. Home Switch should be set as sensitive as possible and should break
within a few degrees of door movement.
Be sure to walk test door after setup is complete.
Perform new learn anytime door operator, control, sensor, or hub is adjusted.
TEACH-IN STAGE HUB LED SENSOR LED
Prior to Learn blue flashing red/green flashing
Network Icon blue flashing & orange solid red solid
Clear Area blue flashing & orange solid red/green flashing
Door Closed Learn blue flashing & orange solid green flashing
Door Opening Learn blue flashing green flashing
Door Open Learn blue flashing green flashing
Door Closing Learn blue flashing green flashing
Floppy Disk blue flashing & orange solid green solid -> green flashing
Hour Glass blue flashing & orange solid green flashing -> red solid -> red/green flashing
Learn Complete orange solid green solid
12
5b
For dual egress doors, Push Door
icon will display. Push right door
(Door B) open at least 10 degrees
1
.