User`s guide

Page 6 of 12 75.5753.02 LZR-MICROSCAN 20140107
DOOR CONTROL HARNESS
WIRE
COLOR:
Green White
Green/
Black
Yellow/
Black
White/
Black
Green/
Red
Yellow/
Red
White/
Red
SIGNAL:
ACT
NO
ACT
COM
SAFE
NO
SAFE
NC
SAFE
COM
STALL
NO
STALL
NC
STALL
COM
Besam 300 / ETIK 13 12 11 12 15 16
Besam MP/CUP 3 4 9 4 5 4
Besam SM900/CU2 1 3 2 3 7 3
Besam SW100
CU-ESD
2
CU-ESD
1
CU-ESD
4
CU-ESD
1
EXU-SA
3
EXU-SA
1
Besam SW200
CU-200
2
CU-200
1
CU-200
4
CU-200
1
EXU-SA
3
EXU-SA
1
Door O Matic Yellow Grey Blue Grey Purple Grey
Dorma 400/700 TRIG GND PRES GND SWING GND
Gyrotech 300/400 Black Red White Red White Red
Gyrotech MAG 6 Black 5 Red 4 White 5 Red 3 Violet 5 Red
Horton 4190 2 3 4 3 10 3
Hunter ACT RTN SAF 1 RTN SAF 2 RTN
Keane Monroe K Green White Red White Yellow White
Record 6000/8000 2 1 8 4 10 11
Stanley L Orange Yellow Red Yellow Blue Yellow
Stanley MP 2 8 7 8 7 8
Stanley 521 TB4-4 TB4-3 TB3-8 TB3-7 TB3-4 TB3-3
Tormax
Input C
#2
Input C
#1
Safety
B #2
Safey B
#1
Safety
A #2
Safety
A #1
INSTALLATION (cont.)
Door Control Harness
1
Door Control
2
Plug Door Control Harness into
hub port labeled Door Control A.
Wire Door Control Harness to
door control.
Wiring
If using independent stall, stall wires on both Door Control Harnesses must be used.
NOTES:
If door system utilizes independent
door controls, repeat steps 1-2 for
the second control. Do not use
door control sync cable.
For dual egress doors with
independent stall, two (2) Door
Control Harnesses must be used.
DOOR TYPE HUB PORT
single always use DOOR CONTROL A hub port
simultaneous pair
from header (access cover) side, left door uses DOOR CONTROL A
hub port and right door uses DOOR CONTROL B hub port
dual egress
from header (access cover) side, whichever door is pushed (right
door) during Teach In process uses DOOR CONTROL B hub port