User`s guide
75.5753.02 LZR-MICROSCAN 20140107 Page 5 of 12
On / Off / Hold Open Switch
1
2
Determine mounting location,
apply mounting template, drill
holes.
Route On / Off / Hold Open Switch
harness and plug into hub port
labeled On / Off / Hold Open.
INSTALLATION (cont.)
If using an existing on / off / hold open switch, plug On
/ Off / Hold Open Switch Jumper into hub port labled
On / Off / Hold Open and wire nut red and black wires
together, or if desired, splice existing switch into Jumper.
FUNCTION JUMPER WIRES
on red jumped to black
hold open black jumped to white
off none
Eagle (Optional)
1 2
1
Install Eagle(s). For complete
installation instructions refer to
BEA User’s Guide 75.0058.
Plug Eagle Harness(es) into hub
port labled Motion 1 and, if
applicable, Motion 2.
Install push plate(s). For complete
installation instructions refer to
the appropriate BEA User’s Guide
1
.
Push
Plate
HUB
COM
NO
2
Wire nut push plate wires (COM
and NO) to grey wires of System
Harness plugged into hub.
Push Plates (Optional)
All periphial devices, including safety, activation, security, and logic
modules should be wired directly to hub and not to door control.
Periphials
NOTES:
Multiple push plates can be
paralleled to grey wires of System
Harness.