User`s guide
Page 4 of 12 75.5753.02 LZR-MICROSCAN 20140107
INSTALLATION
1
HUB
Home
Switch
Home
Switch
2
Install Home Switch at desired
location.
Wire nut white Home Switch wires
to orange wires of System Harness
plugged into hub
2
.
Sensors
MOST BUTT HUNG
MOST CENTER PIVOT
DISTANCE FROM
TOP OF DOOR
MOUNTING HEIGHT RANGE: 6’7” - 8’2”
75.5754.01 20140107 LZR-microscan Mounting Template
microscan
Scan for Product Info
DISTANCE FROM
EDGE OF DOOR
Reference LZR-microscan User’s Guide
75.5753 for full installation instructions
5/16 “
1/8 “
*
*
*
*
sensor
mounting
wire passage
1/8 “
spacer
mounting
LEFT
MOUNT
MOUNTING INSTRUCTIONS
* When using spacer, drill any two (2) spacer mounting
holes and wire passage hole instead of sensor mounting
holes .
When using optional mounting holes
it may be
neccessary to remove end caps or sensor from base.
STEP 2: FOLD ALONG APPROPRIATE
HORIZONTAL AND VERTICAL LINES AND
ALIGN WITH PIVOT EDGE AND TOP OF DOOR
STEP 3: MARK AND DRILL THREE (3) HOLES
*
STEP 1: SURVEY BOTH SIDES OF DOOR TO
DETERMINE APPROPRIATE MOUNTING
LOCATION (DISTANCE FROM PIVOT EDGE
AND DISTANCE FROM TOP OF DOOR),
TAKING INTO ACCOUNT FRAME CLEARANCE,
FINGER GUARD, DOOR ARM, ETC.
STEP 4: FLIP TEMPLATE AND REPEAT FOR
RIGHT SENSOR
NOTES:
Mount sensors as close to top of door and as close to
hinge of door as possible.
Spacer required for applications with hardware
extending across width of door and protruding more
than 2 in.
For thin frame aluminum doors, mounting arm kit
may be used. When using mounting arm kit, do not
use this template.
1 2 3
Use Mounting Template to
position each sensor correctly.
Check for obstructions/clearance.
Align Mounting Template, mark
and drill holes
1
. Repeat on both
sides of door.
Run Slave Sensor Harness through
door.
4 5 6
Mount sensors (using appropriate
screws) by following instructions
on Mounting Template.
Plug in Slave Sensor Harness at
the upper most port on sensor.
Install Door Loop: drill 1/2”
passage hole in header and jamb,
route Master Sensor Harness,
install cap.
7 8
Plug Master Sensor Harness into
hub port labeled Door A Sensors
If necessary, repeat steps 1-7 for
second door leaf using hub port
Door B Sensors.
NOTES:
1: Any dry contact home switch
or auxiliary switch may be used
and must be closed when door
is closed.
2: For simultaneous pairs or
dual egress doors, two (2) Home
Switches must be wired in series
with orange wires of System
Harness plugged into hub.
Switch must “break” as soon as
door begins to open.
NOTES:
1. Spacer required for applications
with door hardware extendeing
across width of door and
protruding more than 2 in.
Do not apply sensor covers until
system is fully operational.
Do not adjust tilt angle.
Home Switch
1
Refer to mounting template for full mounting instructions!