Specifications

Page 5 of 10
75.0082.05 20080125
PROGRAMMING
GUIDE
KEY USER’S ACTIONS DEFAULT LED STATUS
CHECK VALUES
Press the function key that you desire to
inquire about, followed by pressing the
CHECK VALUES key.
After pressing INQUIRY, count the number
of LED flashes – this corresponds to the
setting.
EXAMPLE:
7 = Default sensitivity
value
After pressing a function button, the
red LED flashes quickly. After pressing
the CHECK VALUES key, the LED
flashes the number of the current
setting. No LED flash will indicate a
setting of 0.
SENSITIVITY
SENSITIVITY alters the sensitivity of the IR
field. Values range from 0 to 9, minimum to
maximum respectively. Values can be
programmed separately for door open and
door closed position.
After pressing the SENSITIVITY key,
the red LED flashes quickly. After
pressing a number button, the red LED
flashes slowly.
RELAY HOLD
TIME
RELAY HOLD TIME refers to the hold time
on the output relay of the DK-12. Values
range from 0 to 9.
0 = 1 second
9 = 10 seconds
1 second increments.
0 After pressing the RELAY HOLD TIME
key, the red LED flashes quickly. After
pressing a number button, the red LED
flashes slowly.
RELAY OUTPUT The relay output has 4 possible values:
1 = Normally Closed Relay
2 = Normally Open Relay
3 = Continuous Detection
4 = Continuous Non-Detection
2
After pressing the RELAY OUTPUT
key, the red LED flashes quickly. After
pressing a number button, the red LED
flashes slowly. (Normally Open relay
indicates relay closes upon detection,
and is open upon a power loss).
Door
closed=8
Door
Open= 7