Home Security System User Manual

2 Remote Control Parameters (Continued)
FUNCTION
AFFECTS
INFRARED OR
MICROWAVE
REMOTE
CONTROL
BUTTON
FUNCTION DESCRIPTION
SENSITIVITY MICROWAVE
0 - 9: (7 - Default)
DETECTION
MODE
MICROWAVE
1: Bidirectional (Towards or Away from Sensors)
2: Unidirectional Approach (Towards Sensor)
3: Unidirectional Depart (Away from Sensor)
REJECTION
MODE
MICROWAVE
1: Detection of all kind of Targets
in Motion
2: Detection of all kind of Targets in Motion
+ Interference Immunity
3: Low ‘Pedestrian/Parallel trafc’ Rejection
+ Interference Immunity
4: Medium ‘Pedestrian/Parallel trafc’
Rejection + Interference Immunity
5: High ‘Pedestrian/Parallel trafc’ Rejection
+ Interference Immunity
ACTIVATION
RELAY
HOLD TIME
MICROWAVE
0: 0.5 second
1: 1.0 second
2: 2.0 seconds
3: 3.0 seconds
4: 4.0 seconds
5: 5.0 seconds
6: 6.0 seconds
7: 7.0 seconds
8: 8.0 seconds
9: 9.0 seconds
RELAY
CONFIGURATION
INFRARED
MICROWAVE
Description Active Passive
Detection
COM COM
No Detection
COM COM
NO
NC
NO
NC
NO
NC
NO
NC
Activation
Relay
Presence
Relay
1 Active Passive
2 Passive Active
3 Passive Passive
4 Active Active
OUTPUT
CONFIGURATION
INFRARED
MICROWAVE
PRESENCE RELAY IS40 IS40P
0 - 4: ALL MODES Activates when object is in
presence zone.
Activates when object is
in presence zone.
ACTIVATION RELAY IS40 IS40P
0: STANDARD MODE Activates when motion
detected.
Activates when object is
in presence zone.
1: PULSE ON ENTRY Activates if object motion is
detected and then object enters
presence zone.
Activates when object
enters presence zone.
2: PULSE ON EXIT Activates if object motion is
detected and then object exits
presence zone.
Activaties when object exits
presence zone.
3: PULSE ON ENTRY
FIRST / LAST LINE
(See Example to the Left)
Activates if object motion is
detected and then object enters
presence zone (rst or last line).
Activates when object
enters presence zone (rst
or last line).
4: PULSE ON EXIT
FIRST / LAST LINE
(See Example to the Left)
Activates if object motion is
detected and then object exits
presence zone (rst or last line).
Activates when object exits
presence zone (rst or last
line).
SETUP
INFRARED
MICROWAVE
Initiate Setup, press
DEFAULT
VALUES
INFRARED
MICROWAVE
To set Factory Defaults, press
DOOR EXAMPLE
LAST LINE
FIRST LINE
F1
75.5371.01 EN 20080505 (75.5370) Page 5 of 6
6 3 0 3 6
3
6
9
12
15
18
Height = 16 ft.
S = 3
S = 9
S = 6
FT.
Sensitivity 9, 6, 3
9
0