User manual
75.1038 V3 Jun 2005 [Rev. June 10, 2005]             Page 7 of 8 
PROGRAMMING 
GUIDE Cont. 
MANUAL SET-UP 
TROUBLE-
SHOOTING 
If a remote control is not available, you can adjust the sensitivity parameter ONLY, by means of the push 
buttons + (Plus) and - (Minus). 
The sensor parameters that are not accessible manually will remain at the factory preset values. Pressing the two push buttons, 
located on the circuit board, simultaneously for at least two seconds, will restore all default values. 
The door will not open & LED does not 
light up 
1.  Check supply voltage: 12 to 24 VAC: ± 10% 
 12 to 24 VDC: -10% / +30% 
2.  Check power connector 
The sensor does not respond to the 
remote control 
1.  Check remote control battery insertion 
2.  Check remote control battery voltage 
The sensor does not respond to the code 
entered with the remote control 
1.  Remove the cover and press the 2 buttons 
simultaneously for at least two seconds. This will reset 
the lock code to 0000. Then press the unlock button to 
enable you to access the settings with the remote control. 
The door open and closes constantly  1.  Increase the tilt angle of the antenna 
2. Reduce sensitivity 
DETECTION MODE  3
Detection mode offers 3 different levels of 
detection: Bi-directional, Uni-directional and 
Uni-directional with MTF (motion tracking 
feature). MTF allows the Eagle to switch 
from uni-directional to bi-directional upon 
detection from the normal approach 
direction.
A
fter pressing the DETECTION MODE 
key, the red LED flashes quickly. After 
pressing a number button, the red LED 
flashes slowly. 
 IMMUNITY 
1 = Bi-directional 
2 = Uni-directional 
3 = Uni-directional with MTF
Immunity alters the detection of unwanted 
disturbances within the field of motion 
detection
. 
1 = Extreme sensitivity 
2 = Normal Sensitivity 
3 = Reduced sensitivity
2 
A
fter pressing the IMMUNITY key, the 
red LED flashes quickly. After pressing 
a number button, the red LED flashes 
slowly. 
DEFAULT VALUE
1 = Restores default values for all 
functions 
2 = Boost Mode; Restores default 
values for all functions, and increases 
sensitivity for high-mount applications
. 
A
fter pressing the DEFAULT VALUE 
key, the red LED flashes quickly. After 
pressing a number button, the red LED 
flashes slowly. 
  KEY USER’S ACTIONS  DEFAULT LED STATUS 
+ Press to increase 
sensitivity by one unit 
- Press to decrease sensitivity 
by one unit. 