User`s guide
7
Install EDPS(s)
1. Install the EDPS (Enhanced Door Position Sensor) into the safety side Door Mounted Sensor extrusion as close to the center as possible as
shown above with SuperScans.
2. Plug the previously routed ten pin connector in Step 6 from wiring harness (20.5215.02) into EDPS as shown above.
For a two door system, repeat steps above with the second door.
NOTE: When the DP-Hub is powered the EDPS green LED will illuminate to let you know that it is powered.
NOTE: The EDPS must be placed at the 0 degree angle (horizontal) in the clips as shipped.
5 Installation (continued)
Page 4 of 16 75.5652.03 20130617
6
Install Door Mounted Sensor(s)
(SuperScan shown in example)
Door Mounted 1 Cable
Route to ‘DM 1’
Door Mounted 2 Cable
Route to ‘DM2’
1. For complete installation instructions refer to appropriate Door Mounted Sensor User’s Guide (SuperScan or QuadScan). For a new install,
please make sure to use the DPS Door Mounted Sensor Extrusion Mounting Template, in order to get the extrusion(s) with end caps
installed, approximately 1” apart. For a retro t where the 1” apart cannot be obtained or for more precise Home Switch installation, please refer
to Appendix C.
2. Wire Door Mounted Sensor (SuperScan displayed in this example) harness labeled to the approach/push side
Door Mounted Sensor.
3. Wire Door Mounted Sensor harness labeled to the safety/swing side Door Mounted Sensor.
4. Route wiring harness (20.5215.02) from the Door Mounted Sensor to DP-Hub and plug into DP-Hub at location marked ‘DM1’.
Also note that the extra ten pin connector on the harness should also be routed to the safety side of the door as it will be used for the EDPS
installation in Step 7.
For a two door system, repeat steps above with the second door, except route the second wiring harness from the Door Mounted
Sensor to DP-Hub and plug into DP-Hub at location marked ‘DM2’.
NOTE: If the door system has reective guide rails (for example; stainless steel) set the hold time on the safety side door mounted sensor(s) to
approximately one second.
Door Mounted 1
Door Mounted 2
SuperScan SuperScan
EDPS
10 pin plug from
Door Mounted Sensor Cable
1
2
3
5
6
7
4
8
EMPTY
INHIB GND
INHIB +
N.C.
N.O.
COM
PWR
PWR
GREEN
WHITE
BLACK
RED
Led
Pot
JP2
Make sure to set the SuperScan’s
JP2 to the default (as shown)
to make the SuperScan have a
closed contact during detection.
SuperScan (shown in example)