User`s guide

4
Install BodyGuard
1. For complete installation instructions refer to BodyGuard User’s Guide (75.5134).
NOTE: BEA recommends the use of the Bodymount during all Bodyguard installations.
NOTE: On a single door installation the Bodyguard should be angled to 10 degrees (5 degrees default).
2. Plug ten pin connector into BodyGuard as shown above (hard wire as shown above only if ten pin connector is not available).
3. Route BodyGuard Cable Harness (20.5082) through door header to DP-Hub.
4. Plug BodyGuard Cable into DP-Hub at location labeled ‘BG’.
NOTE: For dual egress use Y-harness for second BodyGuard.
NOTE: For independent dual egrees, two DP-Hubs are required.
5 Installation (continued)
75.5652.03 20130617 Page 3 of 16
5
Install Door Control Harness(s)
1. Make connections to the door control(s) as displayed above.
2. Route wiring harness(s) (20.5222) from door control to DP-Hub and plug into DP-Hub at location marked ‘CONTROL 1’ and/or
‘CONTROL 2’.
NOTE: Typically on the door control, the common (COM) for the Stall input is isolated from the common for Activation and Safety. If the door control
has one common input, tie all the common outputs from the DP-Hub together.
1 PWR
2 PWR
3 COM
4 NO
5 NC
6 IN -
7 IN +
RED
BLACK
WHITE
GREEEN
BROWN
BLUE
10 PIN
10 PIN
BodyGuard Cable
Route to
‘BG’
WIRE OUTPUT
‘TYPICAL DOOR
CONTROL
Green Activation NO ACTIVATION
Yellow Activation NC
White Activation COM COM
Green/Black Safety NO SAFETY
Yellow/Black Safety NC
White/Black Safety COM COM
Green/Red Stall NO STALL
Yellow/Red Stall NC
White/Red Stall COM STALL COM
The DP-Hub provides two door control outputs for door
controls that cannot be paralleled together.
BodyGuard
Door
Control 1
Door
Control 2
For a list of specic door control connections please refer to
Appendix B.
NOTE: BodyGuard Jumper (BodyGuard plug with orange
jumper wire) can be used to setup the system when the
BodyGuard is on the door header cover. It can also be used
in low energy applications.