Instruction Manual

30
t r a n s p o r t i n g a n d s t o r a g e

To prevent fuel spillage when transporting or during temporary storage: 
• The generator should be secured upright in its normal operating 
  position, with the engine switch OFF.
• The fuel cap vent lever is turned to the OFF position.
• Allow the engine to cool well before turning the fuel cap vent lever to 
  the OFF position.

• Do not overfill the tank.(There should be no fuel in the filler neck).
• Do not operate generators while it is on a vehicle. Take the generator off 
  the vehicle and use it in a well-ventilated place.
• Avoid a place exposed to direct sunlight when putting the generator on 
  a vehicle. If the generator is left in an enclosed vehicle for many hours, 
  high temperature inside the vehicle could cause fuel to vaporize 
  resulting in a possible explosion.
• Do not drive on a rough road for an extended period with the 
  generator on board. If you must transport the generator on a rough road, 
  drain the fuel from the generator beforehand.

1. Be sure the storage area is free of excessive humidity and dust.
2. Drain the fuel.

Gasoline is extremely flammable and explosive under 
certain conditions.
Do not smoke or allow flames or sparks in the area.
3. Completely drain the fuel from the tank. Open the fuel valve, stat the 
    engine and operate it in the idle position until all remaining fuel is gone 
    and the engine stops automatically.
4. Discharge oil.
5. Remove spark plug and fill cylinder with 2cc’s fresh oil. Pull start motor 
    3-4 times to discharge the remaining oil. Then reinstall the spark plug.
6. Pull the staring cord slowly until resistance is strong. At this time, the 
    piston is moving to the top of the compression stroke and the valves 
    will be closed.
I2500_3500 Inverter Generator Manual_2011.indd 30 18/10/2011 2:03:54 PM